Description
Elevator contactor DILM32-10C-DS Brief Introduction
|
Product Name |
Elevator contactor |
| Model Number | DILM32-10C-DS
DIL AC-XHI22 DILM150C-XHI22 DILM50C DILM40C DILM17-10C DILM32C-XHI11-S |
|
Quality
|
Original.Brand New
|
|
Payment
|
T/T. Paypal. Western Union
|
|
Delivery
|
3-5 Working Days
|
|
Packaging
|
Packed by carton
|
Elevator Contactor DILM32-10C-DS – Nanjing Zhuye Elevatorparts
The elevator car top emergency power supply is a critical safety component that ensures the elevator’s emergency systems (such as lighting, communication, and door opening) operate normally when the main power supply fails. The Elevator Car Top Emergency Power Supply DJW12-4.5/7.0 provided byNanjing Zhuye Elevatorparts is a high-reliability power supply device tailored for mainstream elevator systems. It supports two capacity specifications (4.5Ah and 7.0Ah) to meet the needs of different elevator models, widely compatible with brands such as Schindler, OTIS, and KONE. Crafted with high-performance lithium-ion batteries, intelligent charging management modules, and flame-retardant casings, this emergency power supply meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator leveling system is a key component that ensures the elevator car aligns accurately with the floor, providing safe and comfortable access for passengers. The elevator leveling sensor serves as the “eye” of this system, detecting the car’s position in real time. The Elevator Leveling Sensor TNC-121 provided by Nanjing Zhuye Elevatorparts is a high-precision position-sensing component tailored for mainstream elevator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, suitable for both passenger and freight elevators. This sensor adopts advanced photoelectric sensing technology, featuring high detection accuracy, fast response speed, and strong anti-interference ability, ensuring the elevator stops stably and accurately at each floor. Crafted with high-quality optical components, sealed metal shells, and precision electronic circuits, it meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator lock is a core safety component that ensures the elevator car door and landing door remain locked during operation, preventing accidental opening and ensuring passenger safety. The Elevator Lock CV50 180 JK406-001 provided by Nanjing Zhuye Elevatorparts is a high-reliability safety lock tailored for mainstream elevator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, suitable for both passenger and freight elevators. This elevator lock integrates precise mechanical structure and stable electrical control, achieving reliable locking when the elevator is running and smooth unlocking when it reaches the floor. Crafted with high-strength alloy steel, flame-retardant plastic, and precision electronic components, it meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator’s electrical control system is prone to arc generation during switch-on and switch-off of contacts, which may cause damage to electrical components or even fire hazards. The elevator arc extinguisher serves as a “safety barrier” to suppress and eliminate arcs. The Elevator Arc Extinguisher HD1.211 provided by Nanjing Zhuye Elevatorparts is a high-performance arc suppression component tailored for elevator electrical systems. It is widely compatible with mainstream elevator brands such as Schindler, OTIS, and KONE, suitable for arc suppression of elevator contactors, relays, and other electrical contacts. Crafted with high-quality arc-extinguishing materials, flame-retardant shells, and precision structural design, this arc extinguisher meets international electrical safety standards (IEC 60947, GB/T 14048) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator door operator is the “power core” of elevator door opening and closing, and the door operator belt serves as a critical transmission component that connects the motor and door pulley system. The Elevator Door Operator Belt L075 provided by Nanjing Zhuye Elevatorparts is a high-performance transmission belt tailored for mainstream elevator door operator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, playing a vital role in ensuring smooth, quiet, and stable operation of elevator doors. Crafted with high-strength polyurethane (PU) material and embedded with high-tensile polyester cords, this belt features excellent wear resistance, tensile strength, and flexibility, meeting international elevator safety standards (EN 81-20, GB 7588) and becoming a trusted choice for global elevator maintenance teams and manufacturers.
The elevator contactor is a core electrical control component that controls the on-off of the elevator’s main circuit and auxiliary circuit, directly determining the stable and safe operation of the elevator. The Elevator Contactor DILM32-10C-DS launched by Nanjing Zhuye Elevatorparts is a high-performance control device tailored for mainstream elevator systems, with excellent compatibility with renowned brands such as Schindler, OTIS, and KONE. It features a rated current of 32A, 1 normally open contact, and a DC coil design, providing reliable switching control for elevator traction machines, door systems, and lighting systems. Crafted with high-quality silver alloy contacts, flame-retardant plastic housing, and precision electromagnetic components, this contactor meets international electrical safety standards (IEC 60947-4-1, GB/T 14048.4) and has become a trusted choice for global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts has always adhered to the concept of “quality first, safety-oriented,” implementing strict quality control throughout the production process of the DILM32-10C-DS elevator contactor. Each unit undergoes rigorous testing, including contact resistance measurement, electromagnetic coil performance verification, mechanical life testing, and flame-retardant rating assessment, ensuring stable parameters and long-term reliable operation. The contactor’s silver alloy contacts have excellent electrical conductivity and wear resistance, with a mechanical life of up to 10 million times and an electrical life of 1 million times. The flame-retardant plastic housing reaches V0 grade, effectively preventing fire risks caused by electrical faults. Its sealed design enhances dust and moisture resistance, making it suitable for the harsh operating environment of elevator machine rooms.
Usage Guide for Elevator Contactor DILM32-10C-DS
DILM32-10C-DS contac such as short circuits or equipment damageCorrect installation, debugging, and calibration of the XAA21751X1/X3 elevator leveling sensor are crucial to ensuring accurate elevator leveling. Nanjing Zhuye Elevatorparts recommends that only certified elevator maintenance technicians perform installation and maintenance to avoid safety hazards caused by improper operation.
1. Pre-Installation Preparation
First, confirm that the elevator’s MAC car lighting controller model matches the POWCV24181MH power supply (check parameters such as input voltage, output voltage, output current, and installation dimensions). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and the secondary power supply for the car lighting system, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator landing doors and machine room entrance. Locate the power supply installation position (usually on the car top or in the car control cabinet) and clean the area to remove dust, debris, and oil stains. Finally, prepare professional tools such as a screwdriver, wire stripper, multimeter, and insulation tester, and check that the new POWCV24181MH power supply from Nanjing Zhuye Elevatorparts is intact (no damage to the shell, no loose pins).
control sysmDILM32-10C-DS contacrated current, coil voltagcontrol cabinetcontrol sysmnchinsulatedcontaccontrolFirst, confirm that the elevator model matches the XAA21751X1/X3 sensor (check parameters such as installation dimensions, signal interface, and rated voltage). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator entrance. Use a hoist to fix the elevator car at a safe position to expose the sensor installation area on the car top. Finally, prepare professional tools such as a screwdriver, wrench, level, multimeter, and calibration ruler; clean the sensor installation position and the corresponding induction plate on the shaft to remove dust, debris, and oil stains .
2. Installation & Wiring
contaccontrolcontaccontacDILM32-10C-DS contacilcontac3main circuit wires (power input and output) to the upper terminals and the control circuit wires (coil power supply) to the lowercoiland check for short circuits between terminalsLocate the original sensor position on the elevator car top and take photos to record its installation height and wiring direction for later reference. Remove the fixing screws of the old sensor and disconnect the wires. Take the new XAA21751X1/X3 sensor from Nanjing Zhuye Elevatorparts, install it on the bracket, and fix it firmly with screws. Use a level to ensure the sensor is horizontally installed—no tilt is allowed . Connect the wires to the corresponding terminals of the elevator control system strictly according to the wiring diagram provided by Nanjing Zhuye, ensuring firm connections and correct polarity. Adjust the distance between the sensor and the induction plate (the standard distance is 5-10mm) to ensure stable signal transmission. After installation, power on the system and use the calibration ruler to debug the sensor’s sensing range, ensuring it can accurately detect the floor position.
3. Daily Maintenance & Post-Installation Testing
controlcontrol cabinetshort circuit, overload, or fault alarms related to the contactor. Press the contactor’s manual test button to check if the contacts switch flexibly without jammingcontaccontacburns, oxidation, or ablation on the contactsloosenesscontaccoil and contact resistancmechanical structure andRestore the elevator’s normal operation mode and test the leveling accuracy at each floor: the gap between the car floor and the landing should be less than 3mm. Operate the elevator to run up and down multiple times to check if the sensor transmits signals stably without delay or loss. For daily maintenance, inspect the sensor during monthly shaft patrols: Check if the fixing screws are loose, the sensor surface is clean (wipe with a dry cloth to remove dust), and the wiring terminals are free of oxidation. Every 3 months, recheck the distance between the sensor and the induction plate and calibrate the sensing accuracy; every 6 months, use a multimeter to test the sensor’s signal output to ensure it meets the standard range. Set up a “protective baffle” around the sensor if necessary to prevent debris from damaging the probe .
Replacement Cycle of Elevator Contactor DILM32-10C-DS
DILM32-10C-DS elevator contacfrequency and working environmentcontrol cabinet3-4contacts, aging of the electromagnetic coil, and attenuation of mechanicalThe replacement cycle of the XAA21751X1/X3 elevator leveling sensor is closely related to operating frequency and the working environment of the shaft. Under normal circumstances (elevator daily operation 12-24 hours, shaft environment dry and low-dust, no frequent vibration), Nanjing Zhuye Elevatorparts recommends a replacement cycle of 3-4 years. This cycle is determined based on long-term field operation data and component aging tests, fully considering the attenuation of the sensing probe, aging of internal circuits, and loss of anti-interference performance.
largedaily operation ≥ 20 hours) or2-3switching accelerates contact wear and coilcomponent corrosion and heat dissipattime <4-5contacFor elevators in high-traffic areas (e.g., large shopping malls, airports with daily operation ≥ 20 hours) or harsh environments (shaft with high humidity, heavy dust, large temperature fluctuations, or severe vibration), the replacement cycle should be shortened to 2-3 years . High-frequency operation accelerates the wear of the sensing probe, while harsh environments cause component corrosion and reduce signal stability. For low-usage elevators (e.g., villa elevators, small office buildings with daily operation time < 8 hours) in stable environments, the cycle can be extended to 4-5 years, but only after inspection and confirmation by Nanjing Zhuye’s technicians that the sensor’s accuracy and signal transmission performance meet standards.
Replace the contactor immediately if any of the following issues occur, regardless of its service life: The contacts are severely burned, ablated, or stuck, causing poor contact or failure to switch; the electromagnetic coil is burned out or fails to pull in, resulting in the contactor not working; the housing is cracked or deformed, losing protective performance; wiring terminals are severely oxidized or loose, causing frequent elevator faults; the contactor produces abnormal noise (e.g., buzzing) during operation that cannot be eliminated by adjustment.
The Elevator Contactor DILM32-10C-DS from Nanjing Zhuye Elevatorparts integrates high reliability, durability, and strong compatibility, providing a critical control guarantee for elevator operation. By following the correct usage, maintenance, and replacement guidelines, you can effectively protect the elevator control system, reduce downtime, and ensure elevator safety. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic DILM32-10C-DS contactors, as well as professional services including model matching, on-site installation guidance, and timely after-sales support. Trust Nanjing Zhuye Elevatorparts for the stable and safe operation of your elevator.