Description
Elevator Door Operator Motor ADR100-SOIC-VKS Brief Introduction
|
Product Name |
Elevator Door Operator Motor |
| Model Number | ADR100-SOIC-VKS
M2000-S01D |
|
Quality
|
Original.Brand New
|
|
Payment
|
T/T. Paypal. Western Union
|
|
Delivery
|
3-5 Working Days
|
|
Packaging
|
Packed by carton
|
Elevator Door Operator Motor ADR100-SOIC-VKS: Core Drive Component from Nanjing Zhuye Elevatorparts
The elevator door operator motor is the “power core” of the elevator door system, responsible for driving the door to open and close smoothly and stably. Its performance directly affects the operation efficiency, noise level, and safety of the elevator door system. The Elevator Door Operator Motor ADR100-SOIC-VKS, exclusively supplied by Nanjing Zhuye Elevatorparts, is meticulously designed for modern passenger and freight elevators. Compliant with international standards such as IEC/EN 60034 and GB 7588, this motor adopts a brushless DC design, featuring high energy efficiency, low noise (≤55dB), and long service life. It boasts wide compatibility with mainstream elevator door operator systems including Schindler, OTIS, KONE, and domestic well-known brands, widely used in residential buildings, commercial complexes, airports, subway stations, and other scenarios, providing reliable power support for elevator door operations.
Nanjing Zhuye Elevatorparts adheres to stringent quality control standards, and the Elevator Door Operator Motor ADR100-SOIC-VKS is a testament to this commitment. Each motor undergoes rigorous pre-delivery testing, including load capacity testing, speed stability verification, high-temperature (up to 100℃) and low-temperature (down to -20℃) resistance tests, and insulation resistance testing. The motor is equipped with a high-precision encoder to ensure accurate speed control and position feedback, realizing smooth door opening and closing without jitter. The stator and rotor are made of high-quality silicon steel sheets and copper windings, which enhance energy conversion efficiency and reduce heat generation during operation. In addition, the motor has a built-in overheat protection and overload protection module, which can automatically cut off the power when an abnormality occurs, effectively preventing motor burnout and ensuring the safety of the door system.
Usage Guide for Elevator Door Operator Motor ADR100-SOIC-VKS
Proper installation, debugging, and daily maintenance are vital to maximizing the service life and operational safety of the ADR100-SOIC-VKS door operator motor. Nanjing Zhuye Elevatorparts strongly recommends that only certified elevator maintenance technicians perform these operations to avoid motor damage, door system jamming, or other safety hazards. Before installation, verify that the motor’s voltage, power, and installation dimensions are completely consistent with the elevator door operator system. For detailed installation steps and parameter setting standards, refer to the product manual provided by Nanjing Zhuye Elevatorparts or contact our technical support team for professional guidance.
1. Pre-Installation Preparation
First, cut off the elevator’s main power supply and the power supply of the door operator system, lock the switch, and place a “Maintenance in Progress” warning sign at the entrance and machine room to prevent accidental startup. Operate the elevator car to the middle floor and secure it with safety supports, then enter the car top to access the door operator device. Prepare professional tools: torque wrenches, screwdrivers, multimeters, cable cutters, and anti-static gloves. Clean the motor installation base and connection interfaces to remove dust, rust, and oil stains—impurities that can affect installation accuracy and electrical contact. Carefully inspect the ADR100-SOIC-VKS motor for external damage (e.g., cracked housing, damaged wiring terminals, or abnormal noise when rotating manually) and confirm that the encoder and protective covers are intact. Check the matching door operator reducer and transmission components to ensure they are free of faults.
2. Installation & Wiring
Fix the ADR100-SOIC-VKS motor on the installation base with high-strength bolts, and tighten the bolts according to the torque specifications provided by Nanjing Zhuye Elevatorparts (usually 30-40 N·m) to avoid loosening during operation. Connect the motor to the door operator reducer: ensure the coupling is aligned accurately, with a coaxiality error of no more than 0.2mm, to reduce vibration and wear. For wiring, strictly follow the wiring diagram: connect the power wires (phase wires and neutral wire) and encoder signal wires to the corresponding terminals of the door operator controller. The wire stripping length should be controlled at 6-8mm, and the wiring terminals should be tightened firmly to prevent poor contact. Separate power wires and signal wires to avoid electromagnetic interference. After wiring, install the wiring protective cover and conduct insulation resistance testing with a multimeter to ensure no short circuit. Finally, manually rotate the motor output shaft to check whether the transmission system operates smoothly without jamming.
Maintenanc3. Daily Maintenance & Use
After installation, restore the power supply and conduct systematic debugging. Use the door operator controller to set key parameters (e.g., door opening/closing speed, acceleration/deceleration time) according to the elevator’s design requirements, with reference to the parameter table provided by Nanjing Zhuye Elevatorparts. Test the door opening and closing operation: check whether the motor runs stably, the speed is uniform, and there is no abnormal noise; verify that the encoder accurately feeds back the door position, ensuring the door stops at the correct position. If there is jitter or speed deviation, adjust the parameters or check the transmission system. For daily maintenance, follow TSG T5002—2017 regulations: inspect the motor monthly for loose fasteners, abnormal noise, or overheating; clean the motor surface and cooling vents with a dry cloth to ensure heat dissipation. Lubricate the transmission components connected to the motor quarterly. For high-traffic elevators, increase the inspection frequency to twice a month. Avoid frequent overload operation of the motor, as this will shorten its service life.
Replacement Cycle of Elevator Door Operator Motor ADR100-SOIC-VKS
The replacement cycle of the ADR100-SOIC-VKS door operator motor depends on usage frequency, operating environment, and maintenance quality. Under normal conditions—12-24 hours of daily operation, stable load, clean and well-ventilated installation environment, and regular maintenance—Nanjing Zhuye Elevatorparts recommends a replacement cycle of 8-10 years. This cycle is based on a large number of field test data and GB/T31821—2015 “Technical Conditions for Scrap of Elevator Main Components”, fully considering the main factors affecting performance, such as wear of bearings, aging of windings, attenuation of encoder accuracy, and reduction of insulation performance.
For elevators in high-traffic areas such as shopping malls, airports, and subway stations, where the daily number of door openings/closing exceeds 3000 times, or in harsh environments with high humidity, heavy dust, high temperature, or frequent voltage fluctuations, the replacement cycle should be shortened to 5-7 years. High-frequency operation accelerates the wear of internal components, and harsh environments easily cause corrosion of the motor housing and insulation damage of windings. For elevators with low usage frequency, such as villa elevators and small office buildings with daily operation time less than 8 hours, proper maintenance can extend the cycle to 10-12 years. However, Nanjing Zhuye Elevatorparts’ technicians should conduct semi-annual comprehensive inspections on motors over 8 years old, including testing insulation resistance, speed stability, and encoder performance.
Regardless of the service life, the ADR100-SOIC-VKS motor should be replaced immediately if any of the following problems occur: the motor makes severe abnormal noise or vibrates violently during operation, which cannot be eliminated by maintenance; the motor overheats frequently (surface temperature exceeds 100℃) or triggers overload protection; the encoder fails, leading to inaccurate door position control or door jamming; the motor windings are burned or the insulation performance is seriously degraded (insulation resistance is less than 1MΩ); the motor housing is severely cracked or corroded, affecting structural integrity; the motor fails to pass the annual safety inspection. Timely replacement of the motor is critical to avoiding door system breakdowns and ensuring passenger safety.
The Elevator Door Operator Motor ADR100-SOIC-VKS from Nanjing Zhuye Elevatorparts combines high efficiency, stability, and durability, making it an ideal choice for elevator maintenance and renovation. Backed by strict quality control, advanced brushless DC technology, and comprehensive after-sales service, it has earned trust from maintenance firms and property managers worldwide. Adhering to proper usage, maintenance, and replacement guidelines minimizes door system failures and enhances the overall operational safety and comfort of the elevator. Nanjing Zhuye Elevatorparts provides 100% genuine ADR100-SOIC-VKS motors, plus professional support including model matching, on-site installation guidance, and fault diagnosis. Choose Nanjing Zhuye Elevatorparts for reliable core components and attentive service tailored to your elevator needs.