Products Categories

Elevator button MTD210 A3N10381

Elevator button MTD210 A3N10381 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Elevator button MTD210 A3N10381 Brief Introduction

Product Name

Elevator button

Model Number MTD210

A3N10381

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Button MTD210 A3N10381: Precision Control Component from Nanjing Zhuye Elevatorparts

Elevator Button MTD210 A3N10381 is a core human-machine interaction component for elevator control systems, designed to receive passenger floor selection and function control commands, and transmit accurate signals to the elevator main controller. With a standardized size and interface, this button is widely compatible with mainstream elevator control systems, featuring sensitive response, clear indicator lights, and durable structure. It is extensively applied in residential buildings, commercial complexes, office towers, airports, and industrial elevators, directly affecting the convenience of passenger use and the stable operation of elevators. Exclusively supplied by Nanjing Zhuye Elevatorparts, a professional and trusted provider of high-quality elevator electrical components, this Elevator Button MTD210 A3N10381 fully complies with international elevator safety standards (EN 81-20, GB 7588) and electrical component technical specifications (IEC 60947). Manufactured with premium materials and precision craftsmanship, it boasts excellent wear resistance, moisture resistance, and anti-interference performance, earning widespread recognition from global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts adheres to the core philosophy of “Precision Response, Durable Operation” and implements rigorous quality control throughout the production and inspection processes of the MTD210 A3N10381 elevator button. Each unit undergoes multi-stage pre-delivery inspections, including contact sensitivity testing, indicator light brightness verification, corrosion resistance detection, and service life testing. The button adopts advanced materials and technologies: the surface is made of high-hardness PC (polycarbonate) material, which is scratch-resistant and wear-resistant, and the key cap has a frosted anti-slip design for comfortable operation; the internal contact uses silver alloy materials to ensure low contact resistance and sensitive response (response time ≤ 50ms); the built-in LED indicator light has adjustable brightness and long service life (≥ 50,000 hours), with clear color distinction (usually red for selected, green for arrival); the standardized A3N10381 interface and mounting hole design enable seamless matching with elevator control panels, simplifying installation and replacement processes. The button has an IP44 protection rating, effectively resisting dust and moisture erosion in elevator cabs.

Step-by-Step Usage Guide for Elevator Button MTD210 A3N10381

To maximize the service life, response sensitivity, and operational stability of the Elevator Button MTD210 A3N10381, both passengers and maintenance personnel should follow the professional guidelines provided by Nanjing Zhuye Elevatorparts:

1. Correct Usage for Passengers

Proper use by passengers is crucial to extending the button’s service life. Follow these simple guidelines: Press the button gently with your finger (avoid using sharp objects such as keys or pens to press, which may scratch the key cap or damage internal contacts); after pressing, confirm that the indicator light on the button is on (red usually indicates the command is received); do not press multiple floor buttons repeatedly to avoid unnecessary load on the elevator control system; if the button indicator light does not turn on after pressing, do not press it violently, and inform the property or elevator maintenance personnel in a timely manner.

2. Professional Installation & Replacement Preparation

Installation and replacement of the MTD210 A3N10381 elevator button must be performed by certified elevator technicians. Prior to operation, refer to the compatibility manual provided by Nanjing Zhuye Elevatorparts to confirm that the button model matches the elevator’s control system and control panel size. The preparation steps are as follows: Cut off the elevator’s main power supply and lock the power switch to prevent accidental power-on; place a “Maintenance in Progress” warning sign at the elevator entrance; open the elevator control panel cover (follow the elevator’s special disassembly procedures) and locate the faulty or to-be-replaced MTD210 A3N10381 button; take a photo of the button’s wiring position to record the connection relationship of each wire, avoiding wrong connection during replacement.

3. Button Replacement & Debugging

  • Old Button Removal: Gently pull out the old button from the control panel mounting hole (some models may need to remove the fixing clip first); disconnect the wires from the old button’s terminal according to the recorded wiring position (use insulated tools to avoid short circuits); clean the mounting hole and terminal area to remove dust and debris.
  • New Button Installation: Take the new MTD210 A3N10381 button from Nanjing Zhuye Elevatorparts, connect the wires to the corresponding terminals according to the photo record (ensure tight connection and correct polarity); align the new button with the mounting hole and press it firmly until it snaps into place (or install the fixing clip as required); close the elevator control panel cover and ensure it is fixed tightly.
  • Post-Installation Debugging: Restore the elevator’s power supply and switch the elevator to inspection mode; press the newly installed button to check if the indicator light is on normally and the response is sensitive; test the elevator’s floor selection function to confirm that the button can accurately transmit signals to the controller and the elevator can reach the designated floor normally; repeat the test 10 times to ensure stable performance without signal loss.

4. Daily Maintenance

Regular maintenance is essential to ensuring the long-term stable operation of the MTD210 A3N10381 elevator button. Maintenance personnel should integrate the following checks into their daily patrol routines: Wipe the button surface with a soft, damp cloth (avoid using corrosive cleaning agents) to remove fingerprints and dust; check if the key cap is loose, cracked, or worn; verify that the indicator light is bright and clear without flickering or dimming; use a multimeter to test the button’s contact resistance periodically (standard resistance ≤ 100mΩ) to ensure sensitive response; check the wiring terminals for looseness or oxidation and tighten or clean them in a timely manner.

Recommended Replacement Cycle for Elevator Button MTD210 A3N10381

As a frequently used human-machine interaction component, the MTD210 A3N10381 elevator button is subject to long-term mechanical pressing, environmental erosion (humidity, dust, temperature changes), and electrical signal transmission, resulting in a specified service life. Timely replacement is crucial to avoiding faults such as insensitive response, indicator light failure, or contact poor contact—issues that may affect passenger use experience or even cause elevator operation confusion.

1. Standard Replacement Cycle

Under normal operating conditions (elevator daily operation time 12–24 hours, daily button pressing times ≥ 500, cab environment temperature -10–40℃, humidity 10%–85%), the recommended replacement cycle for the MTD210 A3N10381 elevator button is3–5 years. This cycle is determined based on Nanjing Zhuye Elevatorparts’ long-term field operation data, material wear tests, and global user feedback on elevator control components.

2. Adjustments for Special Scenarios

  • High-Traffic & Harsh Environments: For elevators in ultra-high-traffic locations (e.g., large airports, central shopping malls) with daily button pressing times ≥ 2000, or in harsh environments (e.g., high-humidity coastal areas, high-dust industrial sites), the replacement cycle is shortened to1.5–2.5 years. Frequent pressing accelerates the wear of internal contacts, while harsh environments cause corrosion of terminals and key cap aging.
  • Low-Frequency Use & Stable Environments: For elevators with low usage frequency (e.g., villa elevators, small office buildings with daily operation time < 8 hours) and stable cab environments (constant temperature and humidity), the replacement cycle can be extended to 5–6 years—only after professional inspection by Nanjing Zhuye Elevatorparts technicians confirms that the button’s response sensitivity, indicator light performance, and contact resistance meet factory standards.

3. Immediate Replacement Conditions

Replace the MTD210 A3N10381 elevator button immediately if any of the following issues occur, regardless of its service life:
  • The button is insensitive to pressing (needs to be pressed hard to respond) or has no response, and the fault persists after checking the wiring and terminals.
  • The indicator light is dim, flickering, or completely off, affecting passengers’ judgment of floor selection status.
  • The key cap is cracked, falling off, or severely worn, affecting the appearance and normal use.
  • Professional testing confirms that the button’s contact resistance exceeds 500mΩ, or there is a short circuit risk, which may affect the stable operation of the elevator control system.
In conclusion, the Elevator Button MTD210 A3N10381 supplied by Nanjing Zhuye Elevatorparts is a high-quality, highly compatible control component tailored for modern elevator systems. By following the correct usage methods, maintenance schedules, and replacement cycles outlined above, elevator maintenance teams can effectively ensure the sensitive response and stable operation of the button, enhance passenger use experience, and minimize downtime. Choosing Nanjing Zhuye Elevatorparts means you not only get 100% authentic MTD210 A3N10381 elevator buttons but also access to professional technical support—including model matching guidance, on-site installation and debugging advice, and prompt after-sales service. Trust Nanjing Zhuye Elevatorparts for the precise control of your elevator system.
Elevator button
Elevator button
Elevator button
Elevator button
Elevator button
Elevator button
Elevator button
Elevator button

 

GET A QUOTE