Products Categories

Elevator Base Station Lock PKG-RUV

The PKG-RUV base station lock is small but mission-critical. By following the installation, testing, and replacement guidelines—and sourcing only from Nanjing Zhuye Elevatorparts—you guarantee code compliance, reduce downtime, and protect every passenger who enters the lift.

Share:

Description

Elevator Base Station Lock

Product Name

Elevator Base Station Lock

Model Number PKG-RUV

PKG-RUN

JY-BX1Y-T

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Base Station Lock PKG-RUV – Usage, Replacement Cycle & Maintenance Guide
By Nanjing Zhuye Elevatorparts

Introduction
The PKG-RUV base station lock is a high-security, electromechanical device designed to prevent unauthorized access to elevator machine rooms, control cabinets, and landing operating panels. Manufactured and distributed worldwide by Nanjing Zhuye Elevatorparts, this IP65-rated lock meets EN 81-20/50, ASME A17.1 and UL 294 standards, delivering 1 million+ mechanical cycles with zero false latching. This 800-word guide covers correct installation, daily operation, and the recommended replacement cycle to keep every elevator secure and code-compliant.

1. Product Highlights
– Lock Type: Rotary vane, 3-point locking, 90° operation
– Contacts: 2-pole change-over, 10 A @ 250 V AC
– Housing: IP65 ABS, anti-UV, –20 °C to +70 °C
– Key: Double-bit brass, 3,000 unique codes, anti-drill
– Rating: 1 million+ mechanical cycles, 50 Nm torque
– Weight: 0.18 kg, snap-fit 30 mm backset

2. Installation Method
Step 1 – Preparation
De-energise the control cabinet; lock-out/tag-out main breaker. Record key code and mounting position.

Step 2 – Positioning
Mount on door header 5 mm before full closure, vane perpendicular to striker (±2°). Use M5 screws, torque 8 N·m.

Step 3 – Wiring
Route 3-core 1.5 mm² cable through PG9 gland. Connect NC contact in series with safety chain; earth housing.

Step 4 – Commissioning
Power-up; door must close fully, contacts change within 1 mm. Log trip distance and technician signature.

3. Daily & Preventive Maintenance
Daily (Technician)
Visual check – vane free, contacts closed, no cracks.

Monthly
Clean vane and striker with 70 % IPA; grease vane sparingly.

Quarterly
Measure contact resistance (<0.1 Ω), insulation (>10 MΩ). Cycle lock 50× under load.

Annually
Replace grease pack and torque screws. Full safety-chain test including governor.

4. Replacement Cycle & Indicators
| Duty | Replace Every | Cycles | Warning Signs |
| Standard | 5–7 years | 1 M | Vane wear >1 mm, >1 Ω resistance |
| Commercial | 3–4 years | 0.6 M | Contact welding, IP65 failure |
| High-speed | 2–3 years | 0.4 M | Striker scoring, vibration >2 g |

Replace immediately if:
– Contact welding or housing cracks
– Repeated “lock fault” without mis-alignment
– Vane temperature >70 °C during normal run

Maintain one spare PKG-RUV per 25 locks for <4-hour response.

5. Why Choose Nanjing Zhuye Elevatorparts?
• Full traceability – laser-etched serial & QR code
• Same-day global dispatch via DHL/FedEx Express
• 24/7 multilingual hotline and on-site training
• Competitive tiered pricing and custom roller sizes for OEM projects

6. Conclusion
The PKG-RUV base station lock is small but mission-critical. By following the installation, testing, and replacement guidelines—and sourcing only from Nanjing Zhuye Elevatorparts—you guarantee code compliance, reduce downtime, and protect every passenger who enters the lift.

Elevator Base Station Lock
Elevator Base Station Lock
Elevator Base Station Lock1
Elevator Base Station Lock1
Elevator Base Station Lock2
Elevator Base Station Lock2
Elevator Base Station Lock4
Elevator Base Station Lock4

GET A QUOTE