Products Categories

CEDES elevator Light Curtain RX/TX-2000-16BCK

CEDES elevator Light Curtain RX/TX-2000-16BCK From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

CEDES elevator Light Curtain RX/TX-2000-16BCK Brief Introduction

Product Name

CEDES elevator Light Curtain

Model Number RX/TX-2000-16BCK
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Nanjing Zhuye Elevator Parts: Premium CEDES Elevator Light Curtain RX/TX-2000-16BCK for Enhanced Door Safety

As a top-tier safety component for elevator door systems, the CEDES Elevator Light Curtain RX/TX-2000-16BCK acts as an “invisible protective shield”—emitting a dense grid of infrared beams between elevator doors to detect even small obstacles, trigger immediate door reversal, and prevent pinching or trapping hazards. Engineered to CEDES’ strict standards for precision, sensitivity, and durability, this RX/TX-2000-16BCK model is designed for universal compatibility with most elevator brands, making it a trusted choice for commercial buildings, residential complexes, hospitals, and high-traffic public facilities worldwide. Nanjing Zhuye Elevator Parts, a leading global supplier of authentic elevator safety components, is proud to offer the CEDES RX/TX-2000-16BCK Light Curtain, crafted to meet international safety regulations and deliver uncompromising protection for passengers and maintenance personnel.
Manufactured with high-performance infrared transmitters/receivers, anti-interference digital circuitry, and rugged, dust-resistant housing, the RX/TX-2000-16BCK excels in obstacle detection accuracy, signal stability, and long-term operational reliability. Its advanced beam-scanning technology ensures no blind spots, while the robust construction withstands frequent door movements and harsh environmental conditions. Nanjing Zhuye Elevator Parts sources this light curtain directly from authorized CEDES manufacturers, subjecting each unit to rigorous quality checks—including sensitivity tests, continuous operation trials, and compatibility verifications—to ensure seamless integration and compliance with global safety standards such as EN 81-20 and ASME A17.1. Whether upgrading aging safety systems, troubleshooting door sensor malfunctions, or conducting routine maintenance, this light curtain provides the safety assurance that elevator maintenance teams and building managers can depend on.

How to Use the CEDES Elevator Light Curtain RX/TX-2000-16BCK

The RX/TX-2000-16BCK is a safety-critical component requiring professional installation and proper maintenance to uphold its protective functionality.
  1. Professional Installation & Alignment: Installation must be performed by certified elevator technicians. Before starting, shut off the elevator’s main power supply and follow lockout-tagout protocols. Mount the TX (transmitter) and RX (receiver) units vertically on the inner edges of the elevator door panels, ensuring they are perfectly aligned—misalignment will disrupt the infrared beam grid. Secure the units with the provided mounting brackets and connect the wiring harnesses to the elevator door controller and power supply, referring to CEDES’ official service manual for precise wiring diagrams. After installation, power on the system and verify operation: when an obstacle (e.g., hands, luggage, or body parts) blocks any beam, the elevator doors should immediately stop closing and reverse to open.
  2. Routine Inspection & Cleaning: Maintenance teams should conduct regular inspections, ideally monthly. Check for loose mounting brackets, damaged wiring, or debris accumulation on the sensor lenses. Test the light curtain’s responsiveness by placing objects of varying sizes (including small items like a pen) in the door path to confirm consistent door reversal. Nanjing Zhuye Elevator Parts recommends cleaning the sensor lenses with a soft, lint-free cloth to remove dust, fingerprints, or smudges—avoid abrasive cleaners or excessive moisture that could scratch the lenses or damage internal circuits. Document inspection results to track performance and identify potential issues early.
  3. Troubleshooting Sensor Malfunctions: If the light curtain fails to detect obstacles, triggers false alarms, or causes erratic door operation, troubleshooting is essential. First, check the power supply and wiring connections to rule out loose or damaged lines. Re-align the TX/RX units if misalignment is visible. Use CEDES-approved diagnostic tools to test signal transmission between the units and check for error codes. For persistent issues such as unresponsive sensors or internal circuit faults, contact Nanjing Zhuye Elevator Parts’ technical support team for expert guidance tailored to CEDES systems.
  4. Safety Precautions: Never attempt installation, adjustment, or maintenance without proper training in elevator safety components. Do not modify the light curtain’s circuitry, lenses, or mounting position, as this compromises detection accuracy and violates safety regulations. Ensure the power supply matches the specified voltage requirements to avoid component damage. Never bypass the light curtain’s safety function, as this exposes passengers to severe pinching or trapping risks.

Replacement Cycle Guidelines for RX/TX-2000-16BCK

Proactive replacement of the light curtain is critical to maintaining elevator door safety and compliance. The replacement cycle is influenced by usage frequency and environmental conditions.
  1. Standard Replacement Cycle: Under normal operating conditions (8-12 hours of daily use in medium-traffic buildings), the RX/TX-2000-16BCK has an average service life of 6-8 years. Nanjing Zhuye Elevator Parts recommends a comprehensive safety audit every 3-4 years to assess sensor sensitivity, signal stability, and component aging.
  2. Factors Shortening Lifespan: High-traffic environments (e.g., airports, shopping malls, or transit hubs) with frequent door operations (over 1,000 cycles per day) may require replacement every 4-5 years. Harsh conditions such as high humidity, extreme temperatures, dust, or chemical exposure can accelerate sensor degradation and circuit wear. Neglecting routine cleaning or inspections also reduces the light curtain’s service life and safety performance.
  3. Key Signs for Replacement: Replace the light curtain if you observe persistent failure to detect obstacles, frequent false alarms despite troubleshooting, physical damage to the TX/RX units (e.g., cracked lenses, broken housing), degraded detection range, or unresponsive triggers. Delaying replacement can lead to safety hazards, non-compliance with regulations, and potential liability risks for building managers.
  4. Replacement Best Practices: Always use a genuine CEDES RX/TX-2000-16BCK from a trusted supplier like Nanjing Zhuye Elevator Parts to ensure compatibility and safety compliance. Label wiring connections before removing the old unit to simplify reinstallation. Install the new light curtain per CEDES’ guidelines, re-align the TX/RX units, and conduct comprehensive functionality tests—including obstacle detection at different positions and door reversal response—before returning the elevator to service. Dispose of the old unit in compliance with local electronic waste regulations.

Why Choose Nanjing Zhuye Elevator Parts?

Nanjing Zhuye Elevator Parts is dedicated to delivering authentic, high-quality elevator safety components and exceptional customer service to clients worldwide. As a trusted supplier of CEDES elevator parts, we prioritize safety, reliability, and transparency—every RX/TX-2000-16BCK Light Curtain meets CEDES’ stringent quality standards and global safety regulations.
Our RX/TX-2000-16BCK is backed by a quality guarantee, and our team of technical experts is available to assist with product selection, installation guidance, troubleshooting, and after-sales support. We offer competitive pricing, efficient global shipping, and a streamlined ordering process, making us the preferred partner for elevator maintenance companies, building managers, and distributors.
Investing in genuine safety components from Nanjing Zhuye Elevator Parts ensures the long-term safety, compliance, and reliability of your elevator system. By following recommended usage and replacement guidelines, you can reduce safety risks, minimize downtime, and enhance passenger trust.
For more information about the CEDES Elevator Light Curtain RX/TX-2000-16BCK or to place an order, contact Nanjing Zhuye Elevator Parts today. We are committed to being your reliable partner for all elevator component needs, delivering quality and peace of mind with every product.
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain
CEDES elevator Light Curtain

 

GET A QUOTE