Products Categories

Elevator brake holding power supply EMK-BZ127AJ EK-EBKP

Elevator brake holding power supply EMK-BZ127AJ EK-EBKP From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Elevator brake holding power supply EMK-BZ127AJ EK-EBKP Brief Introduction

Product Name

Elevator brake holding power supply

Model Number  EMK-BZ127AJ

EK-EBKP

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Brake Holding Power Supply EMK-BZ127AJ & EK-EBKP: Safety Brake Core from Nanjing Zhuye Elevatorparts

Elevator Brake Holding Power Supplies EMK-BZ127AJ and EK-EBKP are critical safety power components engineered for elevator brake systems, responsible for providing stable and reliable DC power to the elevator brake. As the “safety energy core” of elevator braking, these power supplies ensure the brake remains released during elevator operation and rapidly engages to hold the car in place when the elevator stops or loses power—directly preventing accidental car sliding and safeguarding passenger safety. They integrate functions such as AC-DC conversion, voltage stabilization, and overload protection, adapting to the dynamic power demand of elevator brake systems. Exclusively supplied by Nanjing Zhuye Elevatorparts, a professional and trusted provider of high-quality elevator electrical components, the Elevator Brake Holding Power Supply EMK-BZ127AJ & EK-EBKP fully comply with international elevator safety standards (EN 81-20, GB 7588) and power supply technical regulations (IEC 61558). With stable output performance, strong anti-interference capability, and broad compatibility with mainstream elevator brake models, these power supplies are widely utilized in residential, commercial, high-speed, and industrial elevators worldwide.
Nanjing Zhuye Elevatorparts adheres to the core philosophy of “Stable Power Supply, Reliable Brake” and implements rigorous quality control throughout the production and inspection process of EMK-BZ127AJ and EK-EBKP brake holding power supplies. Each unit undergoes a multi-stage pre-delivery inspection protocol, including output voltage stability testing, load capacity verification, anti-interference performance trials, and emergency response detection. The two models share premium performance advantages while catering to different brake power requirements: both adopt high-efficiency rectifier modules and precision voltage stabilization circuits to ensure output voltage fluctuation ≤ ±2%, meeting the strict power demand of elevator brakes; the full-metal shielded housing (IP54 protection rating) effectively resists electromagnetic interference from elevator frequency converters and dust/humidity erosion in the machine room; built-in overload, overvoltage, and short-circuit protection functions automatically cut off power in abnormal situations, preventing damage to the brake and power supply itself. EMK-BZ127AJ is optimized for medium-power elevator brakes (output voltage: 127V DC, rated current: 5A), while EK-EBKP is tailored for high-power elevator brakes (output voltage: 110V/220V DC adjustable, rated current: 8A). With standardized wiring interfaces and mounting dimensions, both models allow for quick and seamless installation, eliminating the need for complex modifications to existing elevator control systems.

Step-by-Step Usage Guide for Elevator Brake Holding Power Supply EMK-BZ127AJ & EK-EBKP

To maximize the performance and service life of EMK-BZ127AJ and EK-EBKP brake holding power supplies, and to ensure the safe and reliable operation of the elevator brake system, strictly follow the professional guidelines provided by Nanjing Zhuye Elevatorparts for installation, debugging, and maintenance:

1. Professional Installation & Wiring

Installation must be conducted by certified elevator technicians proficient in elevator brake systems. Prior to installation, use the detailed compatibility manual provided by Nanjing Zhuye Elevatorparts to confirm that EMK-BZ127AJ/EK-EBKP is compatible with the target elevator’s brake model, rated voltage, and control system. The installation steps are as follows:
  • Safety Preparation: Cut off the elevator’s main power supply and the dedicated power supply of the brake system. Lock the power switch to prevent accidental power-on. Choose a well-ventilated mounting position in the elevator machine room (avoid direct sunlight, high-temperature areas, or humid corners) and clean the surface to remove dust and debris.
  • Power Supply Installation: Fix EMK-BZ127AJ/EK-EBKP to the mounting bracket using high-strength screws provided by Nanjing Zhuye Elevatorparts. Ensure the power supply is installed horizontally (horizontal deviation ≤ 1mm) and the wiring terminals face outward for convenient operation. Check that the mounting position is firm and free of vibration to avoid affecting internal components.
  • Wiring Operation: In accordance with the elevator brake system wiring diagram, connect the power supply’s input terminal (AC 220V/380V) to the mains power and the output terminal (DC 127V for EMK-BZ127AJ; DC 110V/220V for EK-EBKP) to the elevator brake coil. Ensure correct wiring polarity, tight terminal connections, and reliable insulation—use crimp terminals for cable connections to enhance contact stability. Connect the ground wire to the power supply’s grounding terminal to ensure electrical safety. Confirm that the input voltage matches the power supply’s rated input parameters.
  • Post-Installation Debugging: Restore the power supply and switch the elevator to inspection mode. Use a professional multimeter to detect the power supply’s output voltage, ensuring it is within the standard range. Test the elevator’s normal operation and emergency stop functions: confirm the brake releases smoothly when the elevator starts (power supply outputs stable voltage) and engages reliably when the elevator stops or loses power. Check the power supply’s indicator lights (green for normal operation, red for fault) to ensure they work correctly. Conduct a 1-hour continuous operation test to verify the power supply’s temperature rise (normal temperature ≤ 60℃) and output stability.

2. Daily Operation & Routine Inspection

Regular inspections and maintenance are essential to early fault detection and ensuring the long-term stable operation of EMK-BZ127AJ and EK-EBKP power supplies. Maintenance personnel should integrate the following checks into their daily patrol routines:
  • Daily Visual Inspection: During machine room patrols, check the external condition of EMK-BZ127AJ/EK-EBKP. Ensure the metal housing is free of deformation, cracks, or corrosion; the wiring terminals are tight without looseness or oxidation; the power cable and output cable are intact without aging, wear, or insulation damage; the indicator lights show normal status (green for standby/operation).
  • Weekly Performance Check: Use a multimeter to detect the power supply’s input voltage and output voltage, recording the data to check for fluctuations. Test the power supply’s protection functions (e.g., simulate overload or short-circuit conditions under safe operation) to confirm it can trigger protection promptly. Check the connection between the power supply and the brake coil to ensure no poor contact.
  • Monthly Cleaning & Maintenance: Clean the power supply housing and heat dissipation vents with a soft, dry cloth to remove dust and debris, ensuring good heat dissipation. Inspect the internal wiring (after cutting off power) for loose connections or aging; tighten or replace components if necessary. Verify the grounding function to ensure electrical safety compliance.

Recommended Replacement Cycle for Elevator Brake Holding Power Supply EMK-BZ127AJ & EK-EBKP

As core safety power components bearing long-term continuous operation, frequent load switching, and environmental erosion (humidity, dust, temperature fluctuation in the machine room), EMK-BZ127AJ and EK-EBKP elevator brake holding power supplies have specified service lives. Timely replacement is critical to avoiding faults such as unstable output voltage, failure to trigger protection, or complete power supply burnout—issues that may lead to brake failure, accidental car sliding, or even serious safety accidents.

1. Standard Replacement Cycle

Under normal operating conditions (elevator daily operation time 12–24 hours, daily brake engagement/disengagement cycles ≥ 1200, environment temperature 0–40℃, humidity 10%–90%), the recommended replacement cycle for both EMK-BZ127AJ and EK-EBKP is 5–6 years. This cycle is determined based on Nanjing Zhuye Elevatorparts’ long-term field operation data, power supply component aging tests, and global user feedback on elevator brake systems.

2. Adjustments for Special Scenarios

  • Harsh Environments & High-Traffic Scenarios: For elevators in high-humidity coastal areas (salt spray corrosion), machine rooms with poor ventilation (high temperature), or high-traffic areas (e.g., shopping malls, airports) with daily brake cycles ≥ 2000, the replacement cycle should be shortened to 3–4 years. Harsh conditions and frequent use accelerate the aging of internal rectifier modules, capacitors, and resistors, significantly reducing the power supply’s reliability.
  • Low-Frequency Use Scenarios: For elevators with low usage frequency (e.g., villa elevators, small office buildings with daily operation time < 8 hours) and stable machine room environments (constant temperature and humidity), the replacement cycle can be extended to 6–7 years—only if Nanjing Zhuye Elevatorparts’ professional technicians conduct an inspection and confirm that the power supply’s output stability, protection function, and insulation performance are intact and consistent with original factory standards.

3. Immediate Replacement Conditions

Replace EMK-BZ127AJ or EK-EBKP immediately if any of the following issues occur, regardless of its service life:
  • The power supply’s output voltage fluctuation exceeds ±5%, leading to unstable brake operation (e.g., brake slipping, abnormal noise) or failure to release/engage, and the fault persists after parameter adjustment and maintenance.
  • The power supply triggers frequent protection alarms (overload, overvoltage) without obvious external faults, or fails to trigger protection when abnormal conditions occur (e.g., short-circuit), indicating internal protection circuit damage.
  • The power supply has obvious signs of damage, such as burnt smell, bulging capacitors, or damaged wiring terminals, and cannot work normally even after repair.
  • The power supply fails the performance test (e.g., load capacity drops by more than 20%, response time exceeds 100ms), failing to meet the elevator brake system’s power supply requirements.
In conclusion, the Elevator Brake Holding Power Supply EMK-BZ127AJ and EK-EBKP supplied by Nanjing Zhuye Elevatorparts are high-quality, reliable safety power components tailored for different elevator brake power needs. By adhering to the correct usage methods, maintenance schedules, and replacement cycles outlined above, elevator maintenance teams can effectively ensure the stable and safe operation of the elevator brake system, safeguard passenger lives, and minimize safety risks. Choosing Nanjing Zhuye Elevatorparts means you not only get 100% authentic EMK-BZ127AJ and EK-EBKP power supplies but also access to professional technical support—including model matching guidance, on-site installation and debugging advice, and prompt after-sales service. Trust Nanjing Zhuye Elevatorparts for your elevator’s safety power supply needs.
Elevator brake holding power supply