Products Categories

Elevator door knife FED-0701 door lock device 0702

 Elevator door knife FED-0701 door lock device 0702 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

 Elevator door knife FED-0701 door lock device 0702 Brief Introduction

Product Name

 Elevator door knife FED-0701 door lock device 0702

Model Number FED-0701

0702

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Door Knife FED-0701 & Door Lock Device 0702: Linked Safety Core from Nanjing Zhuye Elevatorparts

The Elevator Door Knife FED-0701 and Door Lock Device 0702 form a crucial linked safety system for elevator door operations, working in tandem to control the opening and closing of elevator car doors and landing doors while ensuring interlock safety. The FED-0701 door knife acts as the “drive and control core” that engages with the landing door lock roller to trigger door opening, while the 0702 door lock device serves as the “safety barrier” that locks the landing door when the elevator is not aligned with the floor, preventing accidental door opening and passenger falls. Exclusively supplied by Nanjing Zhuye Elevatorparts (a professional and trusted distributor of high-quality elevator components), the Elevator Door Knife FED-0701 and Door Lock Device 0702 fully comply with international elevator safety standards (EN 81-20, GB 7588) and are compatible with mainstream elevator brands and door system models. Featuring precise linkage performance, high structural durability, and reliable safety protection, this product combination provides solid operational guarantees for elevators in residential buildings, commercial complexes, office towers, hospitals, and other scenarios worldwide.
Nanjing Zhuye Elevatorparts adheres to the core philosophy of “safety first, quality-oriented” and implements strict quality control over both the FED-0701 door knife and 0702 door lock device. Each set undergoes multi-stage pre-delivery inspections, including linkage accuracy testing, lock reliability verification, wear resistance detection, and mechanical life trials. The FED-0701 door knife adopts high-quality carbon steel (Q235) with quenching treatment, ensuring excellent wear resistance and structural rigidity to withstand frequent engagement with the lock roller; the 0702 door lock device features precision-machined lock hooks and a sensitive electromagnetic interlock, with a lock-up force ≥ 1500N to prevent accidental unlocking. Their standardized dimensions and installation interfaces are tailored to match the dedicated mounting positions of compatible elevator door systems, eliminating the need for complex modifications and ensuring seamless linkage.

Step-by-Step Usage Guide for Elevator Door Knife FED-0701 & Door Lock Device 0702

To ensure the reliable operation of the elevator door safety system and extend the service life of the FED-0701 door knife and 0702 door lock device, follow the professional guidelines provided by Nanjing Zhuye Elevatorparts for installation, debugging, and maintenance:

1. Professional Installation & Linkage Debugging

Installation must be performed by certified elevator technicians familiar with elevator door systems. Prior to installation, confirm the compatibility of the FED-0701/0702 combination with the target elevator’s door system model using the detailed compatibility manual provided by Nanjing Zhuye Elevatorparts. The steps are as follows:
  • Safety Preparation: Cut off the elevator’s main power supply and the power supply of the door system, and hang a “Maintenance in Progress—Do Not Power On” sign at the power switch. Fix the elevator car to a safe position aligned with the floor using a safety clamp. Clean the installation areas of the car door (for FED-0701) and landing door (for 0702) to remove dust, oil stains, and debris that may affect installation accuracy.
  • Device Installation: Install the FED-0701 door knife on the car door hanging bracket using high-strength bolts provided by Nanjing Zhuye Elevatorparts, ensuring it is horizontally aligned (tilt angle ≤ 1°) and the knife edge is correctly oriented toward the landing door lock roller. Install the 0702 door lock device on the landing door frame, fixing it firmly and ensuring the lock hook aligns with the lock roller and the electromagnetic interlock is properly connected to the elevator control system. Connect the signal lines of both devices to the elevator main control panel according to the wiring diagram.
  • Linkage Calibration: Adjust the position of the FED-0701 door knife to ensure the gap between the knife edge and the landing door lock roller is 3–5mm when the car door is closed. Operate the car door manually to check the engagement: when the door opens, the door knife should smoothly engage with the lock roller to drive the 0702 door lock device to unlock; when the door closes, the door knife should disengage from the roller, and the 0702 lock hook should lock the landing door immediately. Use a force gauge to verify the 0702 lock-up force (≥ 1500N) and ensure the interlock signal is transmitted accurately to the control system (the elevator cannot start if the landing door is unlocked).
  • Post-Installation Testing: Restore the power supply and conduct comprehensive functional tests. Operate the elevator to run to different floors, checking the linkage performance of FED-0701 and 0702: the landing door should unlock synchronously with the car door when aligned with the floor, and lock immediately after the doors close. Test the emergency unlocking function of the 0702 device (using the dedicated key) to ensure it can be unlocked manually in case of emergencies. Verify there is no abnormal noise during operation and the door opening/closing speed meets the standard. If there is linkage jamming, incomplete locking, or abnormal signal transmission, recheck the installation and calibration immediately.

2. Daily Operation & Routine Inspection

Regular inspections are crucial to early detection of faults in the FED-0701 door knife and 0702 door lock device, ensuring the safety of the elevator door system. Maintenance personnel should incorporate the following checks into their daily patrols:
  • Daily Visual Inspection: During on-site patrols, check the external state of FED-0701 and 0702. Ensure the FED-0701 door knife has no cracks, deformation, or severe wear (wear depth ≤ 0.5mm); the 0702 door lock device’s lock hook is intact, the electromagnetic coil has no overheating discoloration, and the wiring terminals are tight. Check the engagement gap between the door knife and lock roller to confirm it is within the 3–5mm range.
  • Weekly Functional Check: Operate the elevator to open and close the doors multiple times at each floor, listening for abnormal noise (such as friction or collision) from the door knife and lock device. Verify the landing door is tightly locked when the elevator is running and cannot be opened manually from the outside (except with the dedicated key). Check the interlock signal: the elevator should fail to start if the landing door is not fully locked.
  • Monthly Parameter Monitoring: Use a caliper to measure the wear degree of the FED-0701 door knife edge and the 0702 lock hook. Clean the door knife, lock roller, and lock hook with a dry, lint-free cloth to remove dust and oil stains. For elevators in harsh environments, apply a small amount of special lubricant (recommended by Nanjing Zhuye Elevatorparts) to the moving parts of both devices to reduce wear and ensure smooth operation.

3. Regular Maintenance Schedule

Systematic maintenance can effectively extend the service life of the Elevator Door Knife FED-0701 and Door Lock Device 0702. Follow Nanjing Zhuye Elevatorparts’ recommended maintenance plan:
  • Quarterly Maintenance: Disconnect the power supply, remove the FED-0701 door knife and 0702 door lock device (if necessary), and thoroughly clean all components with a professional cleaner. Inspect the door knife for wear (replace if wear depth exceeds 0.5mm) and the lock hook for deformation or wear (replace if lock-up force is less than 1500N). Recheck and tighten all fixed bolts and wiring terminals.
  • Semi-Annual Performance Test: Conduct a comprehensive performance test, including linkage accuracy, lock-up reliability, and interlock signal transmission. Simulate elevator overrun and power failure scenarios to verify that the 0702 door lock device can remain locked and the FED-0701 door knife does not malfunction. For elevators in high-traffic areas (e.g., shopping malls, airports) or harsh environments (high humidity, dust), increase the test frequency and check the door system rail for deformation that may affect device performance.
  • Annual Professional Overhaul: Arrange a professional inspection with Nanjing Zhuye Elevatorparts’ certified technical team. Replace worn components of FED-0701 and 0702 with genuine parts. Recalibrate the linkage gap between the door knife and lock roller and the lock-up force of the 0702 device to meet the original factory performance standards. Inspect the electromagnetic interlock of the 0702 device for sensitivity and replace the coil if necessary.

Recommended Replacement Cycle for Elevator Door Knife FED-0701 & Door Lock Device 0702

As core linked safety components bearing long-term mechanical wear, frequent engagement, and environmental erosion, the FED-0701 door knife and 0702 door lock device have specified service lives. Timely replacement is critical to avoiding linkage failure (such as door knife wear, lock hook deformation, or interlock failure), which may lead to door jamming, inability to open/close, or accidental landing door opening—resulting in passenger injury or elevator downtime.

1. Standard Replacement Cycle

Under normal operating conditions (elevator daily operation time 12–24 hours, daily door opening/closing times ≥ 1000, environment temperature -10–60℃, humidity 10%–95%), the recommended replacement cycle for both the Elevator Door Knife FED-0701 and Door Lock Device 0702 is 2–3 years. It is recommended to replace them simultaneously to ensure optimal linkage performance. This cycle is determined based on Nanjing Zhuye Elevatorparts’ long-term field data, including material wear tests, linkage performance analysis, and actual operation feedback.

2. Adjustments for Special Scenarios

  • Harsh Environments: For elevators in high-humidity coastal areas (salt spray corrosion), high-dust construction sites, or elevators with frequent door operation (more than 2000 times per day), the replacement cycle should be shortened to 1.5–2 years. Harsh conditions accelerate the wear of the door knife edge, corrosion of the lock device, and aging of the electromagnetic coil, significantly reducing the reliability of the linked system.
  • Low-Frequency Use Scenarios: For elevators with low usage frequency (e.g., villa elevators, small office buildings with daily operation time < 8 hours) and clean, stable environments, the replacement cycle can be extended to 3–4 years—only if Nanjing Zhuye’s professional inspection confirms that the linkage accuracy, lock-up reliability, and component integrity of FED-0701 and 0702 are all intact.

3. Immediate Replacement Conditions

Replace the Elevator Door Knife FED-0701 and/or Door Lock Device 0702 immediately if any of the following issues occur, regardless of service life:
  • The FED-0701 door knife is severely worn (wear depth > 0.5mm) or deformed, leading to failure to engage with the lock roller or jamming during door opening/closing.
  • The 0702 door lock device’s lock-up force is less than 1500N, or the lock hook is deformed/cracked; the electromagnetic interlock fails, leading to incorrect signal transmission or inability to lock the landing door.
  • The linked system malfunctions (e.g., landing door fails to unlock when the car door opens, or car door fails to close when the landing door is locked), and the fault cannot be eliminated through maintenance and debugging.
  • The door knife or lock device components are severely rusted (affecting structural strength) or damaged due to impact, posing obvious safety hazards.
In conclusion, the Elevator Door Knife FED-0701 and Door Lock Device 0702 supplied by Nanjing Zhuye Elevatorparts are high-quality, precisely linked safety components tailored for elevator door systems. By following the correct usage methods, maintenance schedules, and replacement cycles, elevator maintenance teams can effectively ensure the stable and safe operation of the elevator door system, improve passenger ride safety, and minimize failure risks. Choosing Nanjing Zhuye Elevatorparts means you get not only authentic FED-0701 door knives and 0702 door lock devices but also professional technical support, including model matching guidance, installation advice, and prompt after-sales service.
Elevator door knife
Elevator door knife
Elevator door knife
Elevator door knife
Elevator door knife
Elevator door knife
Elevator door knife
Elevator door knife

 

GET A QUOTE