Products Categories

XIOLIFT Transformer AC630VC110DN

XIOLIFT Transformer AC630VC110DN From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

XIOLIFT Transformer AC630VC110DN Brief Introduction

Product Name

XIOLIFT Transformer

Model Number  AC630VC110DN
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton
XIOLIFT Transformer AC630VC110DN: Comprehensive Installation, Operation, and Maintenance Guide
The XIOLIFT Transformer AC630VC110DN represents a critical component in modern elevator control systems, providing reliable voltage transformation for various operational circuits. As a specialized elevator transformer manufactured by Xizi (XIOLIFT), this unit plays a vital role in ensuring stable power supply for control systems, door operators, and safety circuits. Nanjing Zhuye Elevator Parts, a leading supplier of elevator components, provides these essential transformers with guaranteed authenticity and superior quality.
Product Overview and Technical Specifications
The AC630VC110DN transformer is specifically designed for elevator applications, featuring a 630V input voltage and 110V output voltage configuration. This step-down transformer provides isolated power supply for elevator control circuits, ensuring safe and reliable operation of critical systems. The unit is rated at 586VA, making it suitable for various elevator control applications including microprocessor-based controllers, door operators, and safety circuits.
Manufactured with high-quality materials and advanced winding technology, the transformer incorporates multiple safety features including thermal protection, overload protection, and short-circuit protection. The unit features Class H insulation materials, ensuring reliable operation even under elevated temperatures. The compact design allows for easy installation in elevator control cabinets while maintaining compliance with international safety standards.
The transformer’s construction includes copper windings for optimal conductivity and efficiency, with vacuum-impregnated insulation providing excellent moisture resistance. The unit is designed for continuous duty operation and can handle the dynamic load variations typical in elevator applications.
Installation Procedure and Setup
Proper installation of the AC630VC110DN transformer requires professional technicians with expertise in electrical systems and elevator controls. The installation process must follow strict safety protocols and electrical codes to ensure safe and reliable operation.
The installation begins with verifying that all power sources are disconnected and properly locked out. Technicians must ensure the elevator control cabinet is de-energized and that all safety procedures are followed. The existing transformer removal process involves carefully documenting all wire connections and their corresponding terminals before disconnection.
Mounting the new transformer requires secure attachment to the control cabinet using appropriate hardware. The unit must be positioned to ensure adequate ventilation and accessibility for maintenance. Clearances should be maintained according to manufacturer specifications to prevent overheating and allow for proper cooling.
Electrical connections must be made following the wiring diagram provided with the transformer. Primary connections (630V input) require proper sizing of conductors and appropriate insulation ratings. Secondary connections (110V output) must be properly terminated and protected. All connections should be tightened to specified torque values and inspected for proper seating.
Grounding connections represent a critical safety requirement. The transformer must be properly grounded according to local electrical codes and manufacturer specifications. Ground conductors should be sized appropriately and connections made to clean, unpainted metal surfaces.
The installation process concludes with comprehensive testing including insulation resistance testing, continuity verification, and operational testing under controlled conditions.
Operational Function and Performance
Once installed and connected, the AC630VC110DN transformer provides reliable voltage transformation for elevator control systems. The unit operates continuously, maintaining stable output voltage despite variations in input voltage and load conditions.
The transformer provides several critical functions:
  1. Voltage Isolation: Electrically isolates control circuits from primary power systems
  2. Voltage Regulation: Maintains stable 110V output for consistent control system operation
  3. Noise Reduction: Filters electrical noise and transients from the primary power supply
  4. Load Distribution: Provides dedicated power supply for various control system components
  5. Safety Protection: Incorporates protection features to prevent damage to connected equipment
The transformer’s design ensures minimal voltage regulation, maintaining output voltage within ±5% of nominal value across the full load range. The unit operates efficiently with low losses, contributing to overall system energy efficiency.
Maintenance Requirements and Replacement Schedule
Regular maintenance of the AC630VC110DN transformer is essential for long-term reliability and safety. The recommended maintenance schedule includes monthly visual inspections, quarterly performance checks, and annual comprehensive testing.
Monthly inspections should focus on visual examination of the transformer for signs of overheating, discoloration, or damage. Technicians should check for unusual noise, vibration, or odor that could indicate developing problems. The transformer temperature should be verified to ensure it operates within normal limits.
Quarterly maintenance involves checking electrical connections for tightness and signs of overheating or corrosion. The transformer should be cleaned to remove dust and debris that could affect cooling. All mounting hardware should be inspected and tightened as necessary. Insulation resistance testing should be performed to detect any degradation of insulation systems.
Annual maintenance requires comprehensive testing including:
  • Insulation resistance testing at rated voltage
  • Turns ratio verification
  • Polarity and phase relationship testing
  • No-load loss measurement
  • Full-load testing if possible
  • Thermal imaging to identify hot spots
The typical replacement cycle for elevator transformers ranges from 10 to 15 years, depending on operating conditions and maintenance quality. However, several factors may necessitate earlier replacement:
  • Insulation Degradation: When insulation resistance falls below acceptable levels
  • Overheating: Persistent high operating temperatures indicating internal problems
  • Electrical Faults: Internal faults such as shorted turns or grounds
  • Physical Damage: Impact damage or corrosion affecting structural integrity
  • Performance Degradation: Excessive voltage regulation or efficiency loss
Signs indicating the need for replacement include persistent overheating despite proper ventilation, unusual noise or vibration during operation, visible damage to windings or insulation, excessive current draw, and failure to maintain rated output voltage.
Nanjing Zhuye Elevator Parts: Your Trusted Partner
Nanjing Zhuye Elevator Parts has established itself as a premier supplier of genuine XIOLIFT elevator components, offering the complete range of AC630VC110DN transformers. With extensive experience in the elevator industry, the company provides not only quality parts but also comprehensive technical support and expertise.
The company’s advantages include guaranteed authentic XIOLIFT components manufactured to original specifications, competitive pricing through direct factory relationships, comprehensive inventory ensuring immediate availability, expert technical support for installation and troubleshooting, worldwide shipping capabilities, and comprehensive warranty coverage.
Conclusion
The XIOLIFT Transformer AC630VC110DN represents a critical component that demands proper installation, regular maintenance, and timely replacement. This specialized elevator transformer provides reliable voltage transformation essential for safe and efficient elevator operation. With Nanjing Zhuye Elevator Parts as your trusted supplier, you gain access to genuine components, expert support, and reliable service. Investing in quality transformers and maintaining them properly is essential for elevator operators committed to safety, reliability, and long-term performance. Regular attention to these critical power components contributes significantly to preventing control system failures and maintaining optimal elevator operation throughout the system’s operational lifespan.
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer
XIOLIFT Transformer

GET A QUOTE