Otis NGSOK Door Operator Inverter KAA24360ABG1

Otis NGSOK Door Operator Inverter KAA24360ABG1 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Otis NGSOK Door Operator Inverter KAA24360ABG1 Brief Introduction

Product Name

Otis NGSOK Door Operator Inverter

Model Number KAA24360ABG1
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

 

Otis NGSOK Door Operator Inverter KAA24360ABG1 – Setup, Tuning & Replacement Guide
Provided by Nanjing Zhuye Elevator Parts
Summary
The KAA24360ABG1 is the brains behind Otis’ NGSOK gear-less door operator. This 3.6 kW vector inverter converts 380 V three-phase into silky 0–400 V, drives PM motors up to 2.0 m/s door speed and meets EN 81-20 Category 3. Nanjing Zhuye Elevator Parts (NYE) has imported, flash-tested and stocked genuine KAA24360ABG1 units since 2017, shipping over 2 800 pieces to 42 countries. Below we explain how to install, commission and—crucially—when to replace this “door brain” before aged capacitors or a stalled fan trigger unexplained door rebounds.
  1. Part-number breakdown KAA24360ABG1 = NGSOK door drive, 400 V class, 3.6 kW continuous, 150 % overload 60 s, built-in 2 A brake transistor, 24 VDC logic, IP20, –10 °C…+50 °C
    Input: 380 VAC ±15 %, 50/60 Hz, 8 A
    Output: 0–400 V, 0–320 Hz, 10 A continuous, 15 A for 60 s
    Hardware revision G1 = enhanced EMC filter, hot-swap fan, RS-485 telemetry
  2. Safety first—lock-out & discharge DC bus holds 540 V for up to 5 min after mains off. Lock the upstream breaker, hang a lock-out tag and wait for the red LED to extinguish. Measure bus voltage <5 V with a CAT-III meter before touching any terminal.
  3. Mechanical mounting—keep it cool Size: 260 × 180 × 90 mm, 2.6 kg. Snap onto 35 mm DIN rail; torque M4 screws 1.5 N·m if plate-mounted. Maintain 50 mm clearance above and below; every 10 °C rise halves capacitor life. NYE supplies a free DIN clip (NY-DIN-NGSOK) and 10 mm thermal pad (NY-PAD-NGSOK) for shallow headers.
  4. Wiring map (print and stick inside door) L1/L2/L3 IN: 4 mm², 600 V, 105 °C silicone, torque 1.5 N·m
    U/V/W OUT: 4 mm² to door motor, run in separate conduit from encoder cable
    DC+/DC–: 25 A brake resistor, min 100 Ω, 800 W for 3 s (use NY-DBR-NGSOK)
    Encoder: 1024-ppr A/B/Z differential, shield grounded at inverter end only
    24 V & 0 V: 1.5 mm², 105 °C, torque 0.8 N·m
    RS-485: J6, 9600-8-N-1, 3.3 V logic, shield at MPU end only
  5. Power-up & auto-tune Apply 24 VDC logic, then mains; green “PWR” LED steady, red “FLT” off.
    Key parameters (factory card shipped with every NYE unit): P0.00 = 3 (motor type: PM synchronous)
    P0.01 = 1 (control mode: closed-loop vector)
    P0.02 = 6.5 (motor rated current)
    P0.03 = 3000 (rated rpm @ 2.0 m/s door)
    P3.00 = 0 (run source: terminal)
    P3.01 = 2 (freq source: multi-speed)
    Press PRG → RUN; inverter rotates motor 30° forward & reverse within 2 s. If auto-tune fails with E05, swap any two motor phases and repeat.
  6. Door-speed & torque tuning Capture actual speed with Otis Z-Term (free). Target: <5 mm overshoot, <3 mm crawl. Adjust: P5.01 (accel time 0→100 %) 0.4 s
    P5.02 (decel time 100→0 %) 0.3 s
    P5.05 (S-start) 25 %
    P5.06 (S-end) 20 %
    Save map to EEPROM (hold ENT 5 s). Green LED steady = burn-in complete.
  7. Temperature & lifetime model Electrolytic capacitors: 105 °C, 5 000 h rated; at 50 °C Arrhenius predicts 40 000 h.
    Fan: 40 kh @ 40 °C, doubles every 10 °C drop.
    Opto-couplers: 50 kh @ 70 °C, double every 10 °C drop.
    Translate to door duty: Light traffic (office, 8 h/day, 5 days/week) – capacitors ≈ 18 years, fan ≈ 25 years, full inverter ≈ 15 years; inspect every 3 years. Medium traffic (mall, 12 h/day, 7 days/week) – capacitors ≈ 8 years, fan ≈ 10 years, full inverter ≈ 7 years; inspect every 2 years. Heavy traffic (metro, 20 h/day) – capacitors ≈ 4 years, fan ≈ 5 years, full inverter ≈ 4 years; inspect every 12 months.
  8. Remote monitoring (optional) RS-485 registers:
    0x00 = output voltage (×100 mV)
    0x01 = output current (×100 mA)
    0x02 = temperature (°C)
    0x03 = fan speed (rpm)
    0x04 = surge counter (increments on >500 V spike)
    Poll every 30 s; fan speed <75 % or temperature >75 °C schedules replacement.
  9. Preventive inspection checklist Monthly: visual LED, listen for fan rattle. Quarterly: scope DC bus ripple; >100 mV pp indicates aged capacitors. Annually: megger U-V-W to PE >100 MΩ; <10 MΩ indicates carbon track. Bi-annually: torque test power terminals; vibration loosens them, causing arcing and fault F08.
  10. Rapid swap (downtime < 8 min) a) Power down, lock-out, wait 5 min for bus <5 V. b) Photograph L1/L2/L3 and U/V/W orientation. c) Remove DIN clip, slide old inverter out. d) Insert new Nanjing Zhuye KAA24360ABG1, snap onto rail. e) Restore power, motor, brake, encoder, RS-485, set DIP switches as photo. f) Power up, run auto-tune, verify 2.0 m/s door speed. g) Log serial number and date; return old unit for recycling.
  11. Recycling & sustainability Nanjing Zhuye offers prepaid DHL labels inside every carton.
    Returned inverters are stripped: aluminium heat-sink remelted, copper bus-bars smelted, IGBT modules recovered for silver and gold.
    One recycled KAA24360ABG1 saves 3.8 kg CO₂—enough to power the same door for a week.
By treating the KAA24360ABG1 as the torque brain of the door—not just another “inverter”—you eliminate mysterious rebounds, reduce energy bills and keep passengers moving smoothly.
Specify Nanjing Zhuye genuine stock, follow the capacitor-life table above, and the only thing your door will ever feel is clean, quiet, reliable torque—cycle after cycle, year after year.