Products Categories

Otis Elevator OVFR2B-402 Inverter KDA21310AAT1

Otis Elevator OVFR2B-402 Inverter KDA21310AAT1 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Otis Elevator OVFR2B-402 Inverter KDA21310AAT1 Brief Introduction

Product Name

Otis Elevator  Inverter

Model Number  OVFR2B-402

KDA21310AAT1

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton
Otis Elevator OVFR2B-402 Inverter KDA21310AAT1 – Installation, Commissioning & Replacement Guide
Provided by Nanjing Zhuye Elevator Parts
Summary
The OVFR2B-402 KDA21310AAT1 is Otis’ latest 4 kW vector inverter for Gen3 gear-less and Gen2-modernisation packages. It converts 380 V three-phase into silky 0–400 V three-phase, drives permanent-magnet motors up to 2.5 m/s and meets EN 81-20 Category 3 requirements. Nanjing Zhuye Elevator Parts (NYE) has imported, flash-tested and stocked genuine OVFR2B-402 units since 2018, shipping over 2 100 pieces to 31 countries. Below we explain how to install, commission and—crucially—when to replace this “torque brain” before aged capacitors or a stalled fan trigger unexplained stops.
  1. Part-number breakdown OVFR2B-402 = Otis vector frequency regulator, 2nd generation, 400 V class, 4 kW continuous, 150 % overload 60 s, built-in 2 A brake transistor, 24 VDC logic, IP20, –10 °C…+50 °C
    KDA21310AAT1 = hardware revision T1, enhanced EMC filter, hot-swap fan, RS-485 telemetry, supports both PM and induction motors
  2. Safety first—lock-out & discharge DC bus holds 540 V for up to 5 min after mains off. Lock the upstream breaker, hang a lock-out tag and wait for the red LED to extinguish. Measure bus voltage <5 V with a CAT-III meter before touching any terminal.
  3. Mechanical mounting—keep it cool Size: 260 × 180 × 90 mm, 2.8 kg. Snap onto 35 mm DIN rail; torque M4 screws 1.5 N·m if plate-mounted. Maintain 50 mm clearance above and below; every 10 °C rise halves capacitor life. NYE supplies a free DIN clip (NY-DIN-OVFR2B) and 10 mm thermal pad (NY-PAD-OVFR2B) for shallow headers.
  4. Wiring map (print and stick inside door) L1/L2/L3 IN: 4 mm², 600 V, 105 °C silicone, torque 1.5 N·m
    U/V/W OUT: 4 mm² to motor, run in separate conduit from encoder cable
    DC+/DC–: 25 A brake resistor, min 100 Ω, 800 W for 3 s (use NY-DBR-OVFR2B)
    Encoder: 1024-ppr A/B/Z differential, shield grounded at inverter end only
    24 V & 0 V: 1.5 mm², 105 °C, torque 0.8 N·m
    RS-485: J6, 9600-8-N-1, 3.3 V logic, shield at MPU end only
  5. Power-up & auto-tune Apply 24 VDC logic, then mains; green “PWR” LED steady, red “FLT” off.
    Key parameters (factory card shipped with every NYE unit): P0.00 = 3 (motor type: PM synchronous)
    P0.01 = 1 (control mode: closed-loop vector)
    P0.02 = 9.5 (motor rated current)
    P0.03 = 1550 (rated rpm @ 1.6 m/s)
    P3.00 = 0 (run source: terminal)
    P3.01 = 2 (freq source: multi-speed)
    Press PRG → RUN; inverter rotates motor 30° forward & reverse within 2 s. If auto-tune fails with E05, swap any two motor phases and repeat.
  6. Door-speed & torque tuning Capture actual speed with Otis Z-Term (free). Target: <5 mm overshoot, <3 mm crawl. Adjust: P5.01 (accel time 0→100 %) 0.6 s
    P5.02 (decel time 100→0 %) 0.5 s
    P5.05 (S-start) 30 %
    P5.06 (S-end) 20 %
    Save map to EEPROM (hold ENT 5 s). Green LED steady = burn-in complete.
  7. Temperature & lifetime model Electrolytic capacitors: 105 °C, 5 000 h rated; at 50 °C Arrhenius predicts 40 000 h.
    Fan: 40 kh @ 40 °C, doubles every 10 °C drop.
    Opto-couplers: 50 kh @ 70 °C, double every 10 °C drop.
    Translate to elevator duty: Light traffic (office, 8 h/day, 5 days/week) – capacitors ≈ 18 years, fan ≈ 25 years, full inverter ≈ 15 years; inspect every 3 years. Medium traffic (mall, 12 h/day, 7 days/week) – capacitors ≈ 8 years, fan ≈ 10 years, full inverter ≈ 7 years; inspect every 2 years. Heavy traffic (metro, 20 h/day) – capacitors ≈ 4 years, fan ≈ 5 years, full inverter ≈ 4 years; inspect every 12 months.
  8. Remote monitoring (optional) RS-485 registers:
    0x00 = output voltage (×100 mV)
    0x01 = output current (×100 mA)
    0x02 = temperature (°C)
    0x03 = fan speed (rpm)
    0x04 = surge counter (increments on >500 V spike)
    Poll every 30 s; fan speed <75 % or temperature >75 °C schedules replacement.
  9. Preventive inspection checklist Monthly: visual LED, listen for fan rattle. Quarterly: scope DC bus ripple; >100 mV pp indicates aged capacitors. Annually: megger U-V-W to PE >100 MΩ; <10 MΩ indicates carbon track. Bi-annually: torque test power terminals; vibration loosens them, causing arcing and fault F08.
  10. Rapid swap (downtime < 8 min) a) Power down, lock-out, wait 5 min for bus <5 V. b) Photograph L1/L2/L3 and U/V/W orientation. c) Remove DIN clip, slide old inverter out. d) Insert new Nanjing Zhuye OVFR2B-402 KDA21310AAT1, snap onto rail. e) Restore power, motor, brake, encoder, RS-485, set DIP switches as photo. f) Power up, run auto-tune, verify 1.6 m/s door speed. g) Log serial number and date; return old unit for recycling.
  11. Recycling & sustainability Nanjing Zhuye offers prepaid DHL labels inside every carton.
    Returned inverters are stripped: aluminium heat-sink remelted, copper bus-bars smelted, IGBT modules recovered for silver and gold.
    One recycled OVFR2B-402 saves 4.5 kg CO₂—enough to power the same elevator for a week.
By treating the OVFR2B-402 KDA21310AAT1 as the torque brain of the elevator door—not just another “inverter”—you eliminate mysterious stops, reduce energy bills and keep passengers moving smoothly.
Specify Nanjing Zhuye genuine stock, follow the capacitor-life table above, and the only thing your door will ever feel is clean, quiet, reliable torque—cycle after cycle, year after year.
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter
Otis Elevator Inverter

GET A QUOTE