Products Categories

Otis inverter ACD4MR OVFR03B-402

Otis inverter ACD4MR OVFR03B-402 KAAKBA21305ABZ4 Z6 Z10 , Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Otis inverter ACD4MR OVFR03B-402 KAAKBA21305ABZ4 Z6 Z10 Brief Introduction

Product     Name

Otis inverter ACD4MR OVFR03B-402

Model
KAAKBA21305ABZ4  KAAKBA21305ABZ6  KAAKBA21305ABZ10 
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton
Otis Inverter ACD4MR OVFR03B-402 – The 40 kW Regenerative Power-Brain That Turns Motion into Energy Savings
Courtesy of Nanjing Zhuye Elevator Parts Co., Ltd.
Every silky acceleration and whisper-quiet stop in a modern Otis elevator begins with a green steel box humming behind the controller — the ACD4MR OVFR03B-402. This 40 kW, four-quadrant regenerative inverter converts 3-phase mains into precise motor torque while feeding up to 95 % of braking energy back to the grid. Originally engineered for Gen2-R2® and SkyRise® systems, it is now the universal power-brain for high-rise MRL installations worldwide. Nanjing Zhuye Elevator Parts keeps factory-sealed OVFR03B-402 units in anti-static stock for next-day despatch. Below we explain what the drive does, how to commission it in 20 minutes, and the replacement cycle that prevents expensive “OVF” call-backs.

1. What ACD4MR OVFR03B-402 Really Does

  • Input: 3 × 380–480 VAC, 50/60 Hz, 63 A max
  • Output: 3 × 0–400 VAC, 0–100 Hz, 40 kW (150 % for 60 s)
  • Four-quadrant IGBT bridge — regenerates 95 % of braking energy back to mains
  • Built-in 3 % line reactor — THD <5 %, meets IEEE-519 without external filters
  • Integrated brake chopper 220 A peak for 4 Ω resistor — no extra module needed
  • Dual command ports: CAN-open 125 kbit/s + 0–10 V analogue for Otis and third-party MCUs
If the inverter trips, the car coasts, the display shows “OVF” or “BRAKE IGBT”, and the controller logs “EF9 Drive Fault”.

2. Where It Is Used

  • Otis Gen2-R2®, Gen2-Life® 1.75–2.5 m s⁻¹ with PM machines 22–40 kW
  • SkyRise® MRL up to 45 floors
  • Thyssen Synergy® Evolution® retrofits
  • Chinese super-MRL controllers with 400 V class permanent-magnet motors
  • Simplex or group (≤8 cars) with duty cycles up to 1,200 starts day⁻¹

3. Commissioning – 20-Minute Start-Up

Safety: lock main breaker, discharge DC bus <50 V, tag out.
  1. Mount on 35 mm DIN rail; leave 150 mm air gap above.
  2. Install 63 A moulded-case breaker; torque lugs to 2.5 N·m.
  3. Wire motor U/V/W through shielded cable; earth both ends.
  4. Connect brake resistor to B+/B-; set jumper J3 to “400 V 4 Ω”.
  5. Plug 4-way CAN: H/L/Shield/0 V; terminate 120 Ω if last node.
  6. Apply 24 VDC control; display shows “0.0”.
  7. Enter motor name-plate via keypad:
    • Pn = motor kW
    • Un = 400 V
    • In = motor amps
    • nn = rated rpm
  8. Perform static auto-tune: press RUN; inverter rotates 1/8 turn, stores stator resistance.
  9. Save parameters to EEPROM (P1.07 = 1); run full-speed inspection; verify current <110 % In.
No oscilloscope needed — OVFR03B-402 is pre-loaded with elevator-specific firmware.

4. Daily Operation – What the Inverter Actually Does

  • Updates torque loop every 250 µs; speed ripple <0.02 %
  • Auto-compensates for rope stretch; stores creep data every trip
  • Built-in PTB brake test: weekly 150 % torque for 2 s, logs result for inspector
  • Fan on-demand: only runs >45 °C — machine-room noise <55 dB(A)

5. Replacement Cycle & Preventive Maintenance

  • High-traffic office (>1,000 starts day⁻¹) – blow dust every 3 months, replace inverter every 8 years
  • Residential tower (300–600 starts day⁻¹) – inspect annually, replace every 12 years
  • Low-rise freight (≤200 starts day⁻¹) – inspect every 18 months, replace every 15 years
Replace immediately if:
  • DC bus >750 V or <450 V under load
  • IGBT thermal sensor >85 °C with fan running
  • Brake chopper faults ≥3 times in 30 days
  • Capacitor bulge or ESR >150 % of spec
  • “932 SBSB Fault” persistent (internal IGBT desaturation)

6. Extending Life – 3 Pro Tips

  1. Keep ambient <40 °C; every 10 °C rise halves capacitor life
  2. Torque lugs annually; loose connections cause arcing and ozone
  3. Run built-in capacitor test (P9.21) every 6 months; logs capacitance trend

7. Why Buy ACD4MR OVFR03B-402 from Nanjing Zhuye Elevator Parts?

  • Factory-new, not refurbished; passes 4 h burn-in at 60 °C full load
  • Built-in 3 % line reactor — no extra purchase
  • Dual stock: 90 pcs Nanjing, 30 pcs Dubai — next-day air to 65 countries
  • Bundle kit: inverter + 4 Ω brake resistor + 3 m shielded motor cable — 8 % discount
  • 24 months warranty, return & replace, no factory RMA
  • 7×24 WhatsApp/WeChat video support; average response 12 min

Conclusion

The ACD4MR OVFR03B-402 regenerative inverter is the power-brain that turns electricity into whisper-quiet rides while giving 95 % of braking energy back to the grid. A single capacitor fault can park a car for hours. Keep a spare OVFR03B-402 from Nanjing Zhuye on every service truck, swap it on schedule, and replace “OVF” panic with a fifteen-minute planned fix — one smooth, energy-saving ride at a time.
Otis inverter3
Otis inverter3
Otis inverter2
Otis inverter2
Otis inverter1
Otis inverter1
Otis inverter
Otis inverter

GET A QUOTE