Products Categories

Elevator Inverter Fan MMF-08L24SS

Elevator Inverter Fan from ZhuYe. The main elevator parts brands are OTIS, Schindler, KONE, SIGMA, Hyundai, Fermator and etc.

Share:

Description

Elevator Inverter Fan

Product Name

Elevator Inverter Fan

Model Number MMF-08L24SS
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Inverter Fan MMF-08L24SS – Usage, Replacement Cycle & Maintenance Guide
By Nanjing Zhuye Elevatorparts

Introduction
The MMF-08L24SS is a high-performance, 24 V DC cooling fan engineered specifically for elevator inverters. Manufactured and distributed worldwide by Nanjing Zhuye Elevatorparts, this IP55-rated, ball-bearing fan meets EN 81-20/50 and ASME A17.1 thermal standards, delivering 80 CFM while reducing inverter temperature rise by up to 15 °C. This 800-word guide covers correct installation, daily operation, and the recommended replacement cycle to keep every elevator drive running safely and efficiently.

1. Product Highlights
– Airflow: 80 CFM @ 24 V DC, 0.32 A (7.7 W)
– Bearing: Dual ball-bearing, 50,000 h @ 40 °C
– Noise: <55 dB(A) @ 1 m
– Rating: IP55, -20 °C to +70 °C, 95 % RH
– Connection: 2-wire 0.75 mm², 3 m PUR, M12 IP67
– Vibration: 10 g continuous, 30 g shock

2. Installation Method
Step 1 – Preparation
De-energise the inverter; lock-out/tag-out and verify zero energy. Record serial number and date code.

Step 2 – Mounting
Position fan 50 mm behind inverter heat sink, aligned with fins. Use supplied anti-vibration grommets; torque M4 screws to 1.2 N·m.

Step 3 – Wiring
Route 2-core cable through PG9 gland. Connect red (+24 V) and black (0 V) to inverter “FAN” terminals. Earth shield at cabinet only.

Step 4 – Commissioning
Power-up; fan must start immediately. Measure airflow with anemometer (>2 m/s). Log current, noise, and temperature drop.

3. Daily & Preventive Maintenance
Daily (Technician)
Visual check—fan rotating, no abnormal noise. Ensure cable gland tight.

Monthly
Clean fan grille and heat sink with compressed air. Check M12 connector tightness.

Quarterly
Measure current (0.32 A ±10 %) and airflow (>2 m/s). Scope test: ripple <5 %, no bearing rattle.

Annually
Replace fan if cumulative hours exceed 40,000 h. Perform full thermal scan of inverter.

4. Replacement Cycle & Indicators
| Duty Cycle | Replace Every | Hours | Warning Signs |
| Standard residential | 6–7 years | 40k | Current >0.4 A, noise >60 dB |
| Commercial / hospital | 4–5 years | 30k | Vibration, temp >70 °C |
| High-speed / outdoor | 2–3 years | 20k | Bearing rattle, IP55 failure |

Replace immediately if:
– Current >0.5 A or <0.2 A
– Bearing rattle, shaft play >0.1 mm
– Repeated “over-temp” faults
– Physical damage or water ingress

Maintain one spare MMF-08L24SS per 20 inverters for <4-hour response.

5. Why Choose Nanjing Zhuye Elevatorparts?
• Full traceability—laser-etched serial and QR code on every fan
• Same-day global dispatch via DHL/FedEx Express
• 24/7 multilingual hotline and on-site training
• Competitive tiered pricing and custom cable lengths for OEM projects

6. Conclusion
The MMF-08L24SS inverter fan is the “thermal bodyguard” of every elevator drive. By following the installation, testing, and replacement guidelines—and sourcing only from Nanjing Zhuye Elevatorparts—you guarantee code compliance, reduce energy costs, and extend inverter life.

Elevator Inverter Fan
Elevator Inverter Fan
Elevator Inverter Fan1
Elevator Inverter Fan1
Elevator Inverter Fan2
Elevator Inverter Fan2
Elevator Inverter Fan3
Elevator Inverter Fan3

 

GET A QUOTE