Elevator light curtain EHC3607101A/102A Brief Introduction

Product Name

Elevator light curtain

Model Number EHC3607101A

EHC3607102A

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Light Curtain EHC3607101A/102A – Nanjing Zhuye Elevatorparts

The elevator light curtain is an indispensable safety component for elevator door systems, forming an invisible “protective barrier” to prevent pinch injuries during door closing. It operates by emitting dense infrared light beams between the door panels; when an obstacle blocks any beam, the system immediately sends a signal to the elevator controller to stop or reverse the doors, ensuring the safety of passengers and goods. The Elevator Light Curtain EHC3607101A/102A series launched by Nanjing Zhuye Elevatorparts is a high-performance safety device tailored for mainstream elevator systems, widely compatible with renowned brands such as Schindler, OTIS, and KONE. Suitable for both passenger and freight elevators, this series adopts advanced infrared sensing technology with high detection accuracy—effectively identifying obstacles as small as standard requirements—and fast response speed, strictly complying with international elevator safety standards (EN 81-20, GB 7588) and becoming a trusted choice for global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts adheres to the “quality first, safety-oriented” principle, implementing strict quality control throughout the production process of the EHC3607101A/102A elevator light curtains. Each unit undergoes rigorous testing, including detection range verification, response time assessment, durability testing, and anti-interference performance inspection. Equipped with high-sensitivity infrared transmitting and receiving tubes, these light curtains can maintain stable operation even in harsh environments such as strong light, dust, and high humidity. The fully sealed metal shell with IP54 protection rating effectively prevents dust and water vapor from entering internal components, while the operating temperature range of -10℃ to 60℃ adapts to various elevator shaft environments. Both EHC3607101A and EHC3607102A models are equipped with a built-in self-diagnosis function, which can promptly detect faults such as wiring disconnections and send alarm signals to facilitate quick maintenance and troubleshooting.

Usage Guide for Elevator Light Curtain EHC3607101A/102A

Correct installation, wiring, and debugging of the EHC3607101A/102A elevator light curtains are crucial to ensuring the safety of the elevator door system. Nanjing Zhuye Elevatorparts strongly recommends that only certified elevator maintenance technicians perform these operations—improper alignment, loose wiring, or incorrect parameter settings may cause light curtain failure, leading to potential pinch hazards or even safety accidents. Before operation, please carefully read the product manual provided by Nanjing Zhuye Elevatorparts and confirm the model matches the elevator door system parameters (such as door width and interface type).

1. Pre-Installation Preparation

First, confirm that the EHC3607101A/102A light curtain is compatible with the elevator’s door width, installation height, and electrical interface. Consult Nanjing Zhuye Elevatorparts’ technical team immediately if there is any doubt about compatibility. Then, strictly follow the safety regulations for elevator maintenance: cut off the elevator’s main power supply and door system power supply, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator entrance and machine room. Fix the elevator car at a flat floor position and use a door stopper to block the door to prevent accidental closing. Prepare professional tools including a screwdriver, wrench, level ruler, multimeter, and anti-static gloves. Clean the installation area (car door and landing door frames) to remove dust, debris, and oil stains, and ensure the mounting surface is flat and free of deformation.

2. Installation, Wiring & Debugging

Install the transmitting and receiving ends of the EHC3607101A/102A light curtain on the car door and landing door frames respectively, ensuring accurate alignment (the deviation should be less than 5mm) and the light beam grid is parallel to the door panel. Fix them firmly with screws according to Nanjing Zhuye’s torque specifications to avoid displacement due to door vibration during operation. Perform wiring strictly according to the wiring diagram provided by Nanjing Zhuye Elevatorparts: Connect the power cord and signal lines to the corresponding terminals of the elevator door controller. Ensure the shielding layer of the signal line is reliably grounded at the controller end to avoid electromagnetic interference, and keep the signal line at least 30mm away from the power line to prevent signal distortion. After wiring, restore the terminal cover before powering on. For debugging: First, perform no-load power-on inspection to confirm the light curtain’s indicator light is normal (green light for normal operation, red light for fault). Use a thin object (such as a wooden stick) to block the light beam in different positions of the door area—the elevator door should stop closing or reverse immediately. Test the self-diagnosis function by disconnecting one of the signal lines; the controller should report a fault alarm promptly. Finally, run the elevator through multiple door opening and closing cycles to ensure the light curtain and door system work synchronously and stably.

3. Daily Use & Maintenance

According to the “Elevator Maintenance Rules” (TSG T5002-2017) and Nanjing Zhuye’s recommendations, the EHC3607101A/102A light curtain should be inspected every 15 days and undergo professional comprehensive testing annually. For daily maintenance: Power off before inspection, clean the surface of the light curtain’s transmitting and receiving ends with a dry cloth or lens cleaning paper to remove dust, fingerprints, and oil stains (avoid using water or chemical cleaners, as they may damage the optical components). Check the fixing screws quarterly and re-tighten them if loose to prevent misalignment. Inspect the signal line for wear, aging, or loose connections—replace damaged lines immediately and ensure the shielding layer is intact. Regularly test the light curtain’s function by blocking the light beam; if the door fails to stop or reverse, or the controller reports frequent light curtain faults, prioritize checking for issues such as misalignment, dirty lenses, or signal interference. If the light curtain fails to work normally, contact Nanjing Zhuye’s after-sales team for troubleshooting in a timely manner to avoid safety risks.

Replacement Cycle of Elevator Light Curtain EHC3607101A/102A

The replacement cycle of the EHC3607101A/102A elevator light curtain is determined by operating frequency, working environment, and component aging. Under normal conditions (elevator daily operation 12-24 hours, door opening and closing ≥500 times/day, dry and clean environment), Nanjing Zhuye Elevatorparts recommends a replacement cycle of 4-6 years. This cycle is based on long-term field operation data and component reliability tests, fully considering the wear of infrared components, attenuation of signal transmission performance, and aging of the shell and wires.
For elevators in high-traffic areas (e.g., large shopping malls, airports with door opening and closing ≥1000 times/day) or harsh environments (high humidity, heavy dust, strong light interference, or frequent vibration), the replacement cycle should be shortened to 2-4 years. High-frequency operation accelerates the aging of infrared tubes and mechanical components, while harsh environments easily cause contamination of lenses and corrosion of wiring. For low-usage elevators (e.g., villa elevators, small office buildings with daily operation time <8 hours) in stable environments, the cycle can be extended to 6-8 years, but annual professional testing by Nanjing Zhuye’s technicians is required to confirm that the light curtain’s detection accuracy, response speed, and anti-interference ability meet safety standards.
Replace the EHC3607101A/102A light curtain immediately if any of the following issues occur, regardless of its service life: Frequent false alarms or failure to detect obstacles, leading to potential pinch hazards; severe damage to the shell (such as cracks or deformation) that affects sealing performance; internal components aging or damage resulting in unstable signal output; the light curtain fails to pass the annual professional safety test; frequent faults that cannot be resolved by maintenance (e.g., continuous self-diagnosis alarms, unresponsive to obstacle blocking). Timely replacement is critical to avoiding elevator operation safety accidents and protecting the lives and property of passengers.
The Elevator Light Curtain EHC3607101A/102A from Nanjing Zhuye Elevatorparts integrates high reliability, high precision, and strong compatibility, providing a critical safety guarantee for the elevator door system. By following the correct usage, maintenance, and replacement guidelines, you can effectively reduce light curtain-related faults and improve the overall operation safety of the elevator. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic EHC3607101A/102A light curtains, as well as professional services including model matching, on-site installation guidance, and timely after-sales support. Trust Nanjing Zhuye Elevatorparts for the safe and stable operation of your elevator.