Elevator door operator inverter HAA24360N1/N2 Brief Introduction

Product Name

Elevator door operator inverter

Model Number HBA24360G13

HAA24360N1

HAA24360N2

HAA24360AK3

HAA24360AE2

HBA24360G11

HBA24360G10

HAA24360AK4

HAA24360AE5

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Door Operator Inverter HAA24360N1/N2 – Nanjing Zhuye Elevatorparts

The elevator door operator inverter is the core control component of the elevator door system, which regulates the speed and torque of the door operator motor to ensure smooth, quiet, and efficient opening and closing of elevator doors. The Elevator Door Operator Inverter HAA24360N1/N2 launched by Nanjing Zhuye Elevatorparts is a high-performance frequency conversion device designed for mainstream elevator door systems, available in two models (HAA24360N1 and HAA24360N2) to match different motor power requirements. It is widely compatible with well-known elevator brands such as Schindler, OTIS, and KONE, suitable for both passenger and freight elevators. Equipped with advanced vector control technology, a user-friendly operation panel, and comprehensive protection functions, this inverter strictly complies with international elevator safety standards (EN 81-20, GB 7588) and has become a reliable choice for global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts adheres to the “quality first, safety-oriented” principle, implementing strict quality control throughout the production process of the HAA24360N1/N2 elevator door operator inverter. Each unit undergoes rigorous testing, including output frequency accuracy verification, load capacity testing, overheating protection assessment, and anti-interference performance inspection. The inverter adopts a high-integration circuit design and a flame-retardant ABS shell, with an IP rating of IP54 to effectively prevent dust and moisture intrusion. It is equipped with a built-in operation panel, allowing maintenance personnel to directly modify parameters and monitor operating status. The comprehensive protection functions include overcurrent, overvoltage, undervoltage, overheating, and motor overload protection, which can quickly cut off the circuit in case of abnormalities to avoid equipment damage. The operating temperature range is -10℃ to 60℃, ensuring stable performance in harsh environments such as elevator shafts and machine rooms.

Usage Guide for Elevator Door Operator Inverter HAA24360N1/N2

Correct installation, wiring, and parameter debugging of the HAA24360N1/N2 elevator door operator inverter are crucial to ensuring the normal operation of the elevator door system. Nanjing Zhuye Elevatorparts strongly recommends that only certified elevator maintenance technicians or electrical engineers perform related operations, as improper wiring or parameter setting may lead to inverter failure, door jamming, or even electrical safety hazards. Before operation, please carefully read the product manual provided by Nanjing Zhuye Elevatorparts.

1. Pre-Installation Preparation

First, confirm that the HAA24360N1/N2 inverter model matches the elevator door operator motor parameters (voltage, power, rated current). Consult Nanjing Zhuye Elevatorparts’ technical team immediately if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and door system power supply, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator entrance and machine room door. Prepare professional tools including a screwdriver, wire stripper, crimping tool, multimeter, and anti-static gloves. Clean the inverter installation area (on the door operator or in the control cabinet) to remove dust, debris, and oil stains. If the inverter is connected to a large-capacity power transformer (above 500kVA), install a power factor correction reactor as required to protect the inverter from grid interference.

2. Installation, Wiring & Debugging

Install the HAA24360N1/N2 inverter on the dedicated bracket and fix it firmly with screws (comply with Nanjing Zhuye’s torque specifications). Perform wiring strictly according to the wiring diagram: Connect the main circuit terminals (L, N for input; U, V, W for output) to the power supply and door operator motor, ensuring correct polarity and firm connections. Connect the control circuit terminals (for door opening/closing signals, door position signals, and safety interlock signals) to the elevator controller, and ensure reliable grounding of the inverter. After wiring, restore the terminal cover before powering on as required to avoid electric shock risks. For debugging: First, perform no-load power-on inspection to confirm that the fan operates normally and the panel displays without errors. Press the “MODE” key to enter the parameter menu, and input the motor’s nameplate parameters (voltage, current, power, speed). Set the acceleration/deceleration time (initially set to 3-5 seconds, and adjust according to actual operation); select the appropriate V/F curve based on the door system load characteristics. Note that key parameters such as P08 and P09 need to be modified after pressing the “STOP” key. Press the “FWD” or “REV” key to perform no-load operation of the motor, and check if the rotation direction is correct (swap any two of U/V/W if reversed). Then, perform load test: switch to normal mode, open and close the door repeatedly, observe if the door operates smoothly, and adjust the acceleration/deceleration time or torque compensation parameter if there is jitter or slow response. Finally, confirm all protection functions are effective by simulating fault conditions (e.g., overcurrent).

3. Daily Maintenance & Inspection

According to the “Elevator Maintenance Rules” (TSG T5002-2017) and Nanjing Zhuye’s recommendations, the HAA24360N1/N2 inverter should be inspected monthly and undergo professional comprehensive testing annually. For daily maintenance: Power off before inspection, and confirm the internal high-voltage indicator light is off before operation. Clean the inverter shell and heat sink with a dry cloth or vacuum cleaner to remove dust (avoid using water or chemical cleaners). Check the wiring terminals for looseness, oxidation, or burning, and re-tighten or clean them if necessary. Inspect the cooling fan for abnormal noise or stuck rotation, and replace it immediately if faulty (the fan’s service life is about 2-3 years). Every 3 months, open the inverter cover (by professional technicians) to check for dust accumulation on the circuit board, and clean it with compressed air if needed. Regularly check the electrolytic capacitors for leakage, bulging, or deformation—replace them if any abnormalities are found (the service life of electrolytic capacitors is about 5 years). If the inverter displays fault codes, refer to the manual or contact Nanjing Zhuye’s after-sales team for troubleshooting.

Replacement Cycle of Elevator Door Operator Inverter HAA24360N1/N2

The replacement cycle of the HAA24360N1/N2 elevator door operator inverter is determined by operating frequency, working environment, and component aging. Under normal conditions (elevator daily operation 12-24 hours, stable voltage, dry and clean environment), Nanjing Zhuye Elevatorparts recommends a replacement cycle of 5-7 years. This cycle is based on long-term field operation data and component reliability tests, fully considering the aging of internal electronic components (such as electrolytic capacitors), attenuation of cooling system performance, and degradation of frequency conversion control accuracy.
For elevators in high-traffic areas (e.g., large shopping malls, airports with door opening and closing ≥1000 times/day) or harsh environments (high humidity, heavy dust, frequent voltage fluctuations, or strong electromagnetic interference), the replacement cycle should be shortened to 3-5 years. High-frequency operation accelerates the wear of internal components and cooling fans, while harsh environments easily cause circuit board corrosion and signal interference. For low-usage elevators (e.g., villa elevators, small office buildings with daily operation time <8 hours) in stable environments, the cycle can be extended to 7-8 years, but annual professional testing by Nanjing Zhuye’s technicians is required to confirm that the inverter’s output performance, protection functions, and parameter stability meet safety standards.
Replace the HAA24360N1/N2 inverter immediately if any of the following issues occur, regardless of its service life: Frequent fault alarms (overcurrent, overheating, undervoltage) that cannot be resolved by maintenance; significant degradation of door operation performance (uneven speed, jitter, or slow response) even after parameter adjustment; severe damage to the inverter shell, water ingress, or circuit board burnout; failure to pass the annual professional safety test; internal components (e.g., cooling fan, capacitors) are severely aged or damaged, affecting normal operation. Timely replacement is critical to avoid door operation failure, which may cause passenger trapping or other safety hazards.
The Elevator Door Operator Inverter HAA24360N1/N2 from Nanjing Zhuye Elevatorparts integrates high reliability, high efficiency, and strong compatibility, providing a critical technical guarantee for the stable operation of elevator door systems. By following the correct usage, maintenance, and replacement guidelines, you can effectively reduce door system faults and improve passenger riding experience. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic HAA24360N1/N2 inverters, as well as professional services including model matching, on-site debugging guidance, and timely after-sales support. Trust Nanjing Zhuye Elevatorparts for the safe and stable operation of your elevator.