Products Categories

Elevator leveling sensor SH-GS3W4

Elevator leveling sensor SH-GS3W4 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Elevator leveling sensor SH-GS3W4 Brief Introduction

Product Name

Elevator leveling sensor

Model Number SH-GS3W4
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Leveling Sensor SH-GS3W4 – Nanjing Zhuye Elevatorparts

The elevator car top emergency power supply is a critical safety component that ensures the elevator’s emergency systems (such as lighting, communication, and door opening) operate normally when the main power supply fails. The Elevator Car Top Emergency Power Supply DJW12-4.5/7.0 provided byNanjing Zhuye Elevatorparts is a high-reliability power supply device tailored for mainstream elevator systems. It supports two capacity specifications (4.5Ah and 7.0Ah) to meet the needs of different elevator models, widely compatible with brands such as Schindler, OTIS, and KONE. Crafted with high-performance lithium-ion batteries, intelligent charging management modules, and flame-retardant casings, this emergency power supply meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator leveling system is a key component that ensures the elevator car aligns accurately with the floor, providing safe and comfortable access for passengers. The elevator leveling sensor serves as the “eye” of this system, detecting the car’s position in real time. The Elevator Leveling Sensor TNC-121 provided by Nanjing Zhuye Elevatorparts is a high-precision position-sensing component tailored for mainstream elevator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, suitable for both passenger and freight elevators. This sensor adopts advanced photoelectric sensing technology, featuring high detection accuracy, fast response speed, and strong anti-interference ability, ensuring the elevator stops stably and accurately at each floor. Crafted with high-quality optical components, sealed metal shells, and precision electronic circuits, it meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator lock is a core safety component that ensures the elevator car door and landing door remain locked during operation, preventing accidental opening and ensuring passenger safety. The Elevator Lock CV50 180 JK406-001 provided by Nanjing Zhuye Elevatorparts is a high-reliability safety lock tailored for mainstream elevator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, suitable for both passenger and freight elevators. This elevator lock integrates precise mechanical structure and stable electrical control, achieving reliable locking when the elevator is running and smooth unlocking when it reaches the floor. Crafted with high-strength alloy steel, flame-retardant plastic, and precision electronic components, it meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator’s electrical control system is prone to arc generation during switch-on and switch-off of contacts, which may cause damage to electrical components or even fire hazards. The elevator arc extinguisher serves as a “safety barrier” to suppress and eliminate arcs. The Elevator Arc Extinguisher HD1.211 provided by Nanjing Zhuye Elevatorparts is a high-performance arc suppression component tailored for elevator electrical systems. It is widely compatible with mainstream elevator brands such as Schindler, OTIS, and KONE, suitable for arc suppression of elevator contactors, relays, and other electrical contacts. Crafted with high-quality arc-extinguishing materials, flame-retardant shells, and precision structural design, this arc extinguisher meets international electrical safety standards (IEC 60947, GB/T 14048) and has become a trusted choice for global elevator maintenance teams and manufacturers.
The elevator door operator is the “power core” of elevator door opening and closing, and the door operator belt serves as a critical transmission component that connects the motor and door pulley system. The Elevator Door Operator Belt L075 provided by Nanjing Zhuye Elevatorparts is a high-performance transmission belt tailored for mainstream elevator door operator systems. It is widely compatible with elevator brands such as Schindler, OTIS, and KONE, playing a vital role in ensuring smooth, quiet, and stable operation of elevator doors. Crafted with high-strength polyurethane (PU) material and embedded with high-tensile polyester cords, this belt features excellent wear resistance, tensile strength, and flexibility, meeting international elevator safety standards (EN 81-20, GB 7588) and becoming a trusted choice for global elevator maintenance teams and manufacturers.
The elevator leveling system is a vital part of ensuring safe and comfortable elevator operation, as it ensures the elevator car aligns accurately with the landing floor. The elevator leveling sensor, acting as the “eyes” of this system, detects the car’s real-time position and transmits precise signals to the control unit. The Elevator Leveling Sensor SH-GS3W4 launched by Nanjing Zhuye Elevatorparts is a high-performance sensor designed for mainstream elevator systems. It boasts wide compatibility with renowned brands such as Schindler, OTIS, and KONE, making it suitable for both passenger and freight elevators. Adopting advanced photoelectric sensing technology, this sensor features fast response, strong anti-interference capability, and stable signal transmission. Manufactured with high-quality optical components, sealed metal casings, and precision electronic circuits, it complies with international elevator safety standards (EN 81-20, GB 7588) and has become a preferred choice for global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts has always adhered to the concept of “quality first, safety-oriented,” implementing strict quality control throughout the production process of the SH-GS3W4 elevator leveling sensor. Each unit undergoes rigorous testing, including positioning accuracy calibration, response time detection, environmental adaptability verification, and durability assessment. The sensor achieves a positioning accuracy of ±0.8mm, ensuring the elevator car aligns perfectly with the landing floor threshold. Its response time is less than 0.02s, enabling rapid signal feedback to the control system for smooth and stable stopping. The sealed metal casing has an IP65 protection rating, effectively resisting dust, moisture, and vibration in the elevator shaft. It can operate stably in a temperature range of -20℃ to 65℃, adapting to the harsh operating environments of various buildings.

Usage Guide for Elevator Leveling Sensor SH-GS3W4

Correct installation, calibration, and maintenance are crucial to maximizing the performance of the SH-GS3W4 elevator leveling sensor. Nanjing Zhuye Elevatorparts emphasizes that only certified elevator maintenance technicians are allowed to perform related operations, as improper use may lead to inaccurate leveling, affecting passenger safety and comfort.

1. Pre-Installation Preparation

1. Pre-Installation Preparation

First, confirm that the elevator’s MAC car lighting controller model matches the POWCV24181MH power supply (check parameters such as input voltage, output voltage, output current, and installation dimensions). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and the secondary power supply for the car lighting system, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator landing doors and machine room entrance. Locate the power supply installation position (usually on the car top or in the car control cabinet) and clean the area to remove dust, debris, and oil stains. Finally, prepare professional tools such as a screwdriver, wire stripper, multimeter, and insulation tester, and check that the new POWCV24181MH power supply from Nanjing Zhuye Elevatorparts is intact (no damage to the shell, no loose pins).
First, confirm that the elevator control system model matches the SH-GS3W4 leveling sensor (check parameters such as working voltage, signal type, and installation dimensions). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and the power supply of the leveling system, lock the switch, and place a “Maintenance in Progress” warning sign at the machine room entrance and landing doors. Use a hoist to fix the elevator car at a middle floor to ensure a safe operation space. Finally, prepare professional tools such as a screwdriver, wrench, multimeter, and level ruler, and clean the sensor installation position (on the car or guide rail) to remove dust, rust, and debris.

2. Installation & Calibration

If replacing the old sensor, first take photos to record its installation position, wiring direction, and terminal connections for later reference. Disconnect the wires from the old sensor according to the labels and remove the old sensor. Take the new SH-GS3W4 leveling sensor from Nanjing Zhuye Elevatorparts, install it on the preset position with screws, and ensure it is vertical and aligned with the leveling plate on the guide rail (use a level ruler for calibration). Connect the wires to the corresponding terminals strictly following the photos and the wiring diagram provided by Nanjing Zhuye: Connect the power line to the “DC24V” terminal, the signal line to the “SIG” terminal, and the ground line to the “GND” terminal. After wiring, calibrate the sensor: Operate the elevator to each floor, adjust the sensor’s height so that the signal is triggered accurately when the car is level with the floor; use a multimeter to check the signal output, which should be stable without interference.

Debugg3. Operation & Daily Maintenance

Remove the hoist fixing the car, restore the power supply, and switch the elevator to inspection mode. Operate the elevator to run up and down all floors repeatedly, checking the leveling accuracy at each floor: The gap between the car floor and the landing floor should not exceed 1mm, and there should be no obvious vibration when stopping. After 2 hours of stable operation, stop the elevator and inspect the sensor again to confirm no loose wiring, abnormal heating, or signal interference. For daily maintenance, inspect the sensor during monthly shaft patrols: Check if the shell is damaged, the lens is dirty, and the wiring terminals are tight; clean the lens with a dry cloth to ensure accurate detection. Every 3 months, use a multimeter to test the power supply and signal output; every 6 months, re-calibrate the sensor’s position to ensure consistent leveling accuracy.

Replacement Cycle of Elevator Leveling Sensor SH-GS3W4

The replacement cycle of the SH-GS3W4 elevator leveling sensor is closely related to the operating environment and usage frequency. Under normal circumstances (elevator daily operation 12-24 hours, shaft environment dry and low-dust, no frequent vibration), Nanjing Zhuye Elevatorparts recommends a replacement cycle of 2-3 years. This cycle is determined based on long-term field operation data, optical component aging tests, and electronic circuit performance assessments, fully considering the attenuation of positioning accuracy and the wear of mechanical components.
For elevators in high-traffic areas (e.g., large shopping malls, airports with daily operation ≥ 20 hours) or harsh environments (e.g., high humidity, heavy dust, strong electromagnetic interference, frequent vibration), the replacement cycle should be shortened to 1-1.5 years. High-frequency operation accelerates the aging of optical and electronic components, while harsh environments affect signal stability and sensor durability. For low-usage elevators (e.g., villa elevators, small office buildings with daily operation time < 8 hours) in stable environments, the cycle can be extended to 3-4 years, but only after inspection and confirmation by Nanjing Zhuye’s technicians that the sensor’s positioning accuracy and signal stability meet safety standards.
Replace the sensor immediately if any of the following issues occur, regardless of its service life: The elevator has obvious leveling deviation (gap exceeding 3mm) that cannot be corrected by calibration; the sensor signal is unstable or lost, causing the elevator to overshoot, undershoot, or fail to stop; the sensor lens is severely scratched or fogged, affecting detection; the shell is severely damaged, deformed, or corroded; the sensor has no signal output or abnormal heating during operation; the elevator frequently reports leveling system faults confirmed to be caused by the sensor.
The Elevator Leveling Sensor SH-GS3W4 from Nanjing Zhuye Elevatorparts integrates high-precision positioning, durability, and strong compatibility, providing a solid technical guarantee for elevator leveling systems. By following the correct usage, maintenance, and replacement guidelines, you can effectively ensure the elevator’s accurate and stable leveling, improve passenger riding comfort, and reduce faults caused by leveling deviations. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic SH-GS3W4 leveling sensors, as well as professional services including model matching, on-site calibration guidance, and timely after-sales support. Trust Nanjing Zhuye Elevatorparts for the safe and comfortable operation of your elevator.
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor
Elevator leveling sensor

 

GET A QUOTE