Products Categories

Elevator door lock contact switch SEL1-A1ZP

Elevator door lock contact switch SEL1-A1ZP From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Elevator door lock contact switch SEL1-A1ZP Brief Introduction

Product Name

Elevator door lock contact switch

Model Number SEL1-A1ZP
 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Door Lock Contact Switch SEL1-A1ZP – Nanjing Zhuye Elevatorparts

The elevator door lock system is a critical safety barrier for elevator operation, and the door lock contact switch acts as the “core safety switch” that ensures the elevator can only start when the door is fully locked. The Elevator Door Lock Contact Switch SEL1-A1ZP provided by Nanjing Zhuye Elevatorparts is a high-reliability safety component tailored for modern elevator door lock systems. It is widely compatible with mainstream elevator brands such as Schindler, OTIS, and KONE, and is essential for signal transmission and circuit control of the door lock system. This switch strictly controls the elevator’s operation circuit—only when the elevator door is completely locked and the switch is closed can the elevator start running, effectively preventing accidents caused by elevator operation with the door open. Crafted with high-quality silver alloy contacts, high-temperature resistant insulating materials, and a dust-proof and waterproof shell, it meets international elevator safety standards (EN 81-20, GB 7588) and has become a trusted choice for global elevator maintenance teams and manufacturers.
Nanjing Zhuye Elevatorparts adheres to the core philosophy of “Safe Locking, Reliable Switching” and implements strict quality control throughout the production process of the SEL1-A1ZP door lock contact switch. Each unit undergoes rigorous testing, including contact resistance detection, electrical life assessment, high-temperature resistance testing, and corrosion resistance verification. The silver alloy contacts have extremely low contact resistance (≤ 25mΩ) and excellent electrical conductivity, ensuring stable signal transmission even after long-term high-frequency use. The switch’s insulating base is made of flame-retardant PA66 material, which can withstand high temperatures up to 180℃ and has excellent flame-retardant and arc-extinguishing properties. With an electrical life of ≥ 800,000 times and a mechanical life of ≥ 1.2 million times, it can withstand the frequent opening and closing of elevator doors. The IP65 protection rating shell effectively resists dust, moisture, and slight water splashing in the elevator shaft, ensuring reliable operation in harsh environments.

Usage Guide for Elevator Door Lock Contact Switch SEL1-A1ZP

Correct installation, adjustment, and maintenance are crucial to ensuring the reliable performance of the SEL1-A1ZP elevator door lock contact switch. Nanjing Zhuye Elevatorparts emphasizes that only certified elevator maintenance technicians are allowed to perform related operations, as improper use may lead to door lock failure or serious elevator safety hazards.

1. Pre-Installation Preparation

1. Pre-Installation Preparation

First, confirm that the elevator’s MAC car lighting controller model matches the POWCV24181MH power supply (check parameters such as input voltage, output voltage, output current, and installation dimensions). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and the secondary power supply for the car lighting system, lock the switch, and place a “Maintenance in Progress” warning sign at the elevator landing doors and machine room entrance. Locate the power supply installation position (usually on the car top or in the car control cabinet) and clean the area to remove dust, debris, and oil stains. Finally, prepare professional tools such as a screwdriver, wire stripper, multimeter, and insulation tester, and check that the new POWCV24181MH power supply from Nanjing Zhuye Elevatorparts is intact (no damage to the shell, no loose pins).
First, confirm that the elevator door lock model matches the SEL1-A1ZP contact switch (check parameters such as contact type, installation dimensions, and rated voltage/current). Consult Nanjing Zhuye Elevatorparts’ technical team if there is any uncertainty about compatibility. Then, cut off the elevator’s main power supply and the secondary power supply for the door lock system, lock the switch, and place a “Maintenance in Progress” warning sign at the landing doors and machine room entrance. Fix the elevator door in a closed state with wooden wedges to prevent accidental movement. Finally, prepare professional tools such as a screwdriver, wire stripper, multimeter, and contact cleaner, and clean the door lock’s contact switch installation position to remove dust, oxidation, and debris.

2. Installation & Wiring

If replacing the old contact switch, first take photos to record the wiring positions and switch installation direction for later reference. Use a screwdriver to remove the fixing screws of the old switch, disconnect the wires according to the labels, and take out the old switch. Inspect the door lock’s switch base for oxidation, wear, or deformation (clean with contact cleaner or replace if necessary). Take the new SEL1-A1ZP contact switch from Nanjing Zhuye Elevatorparts, install it in the correct direction on the door lock base, and fix it firmly with screws. Connect the wires to the corresponding terminals strictly following the photos and the wiring diagram provided by Nanjing Zhuye—ensure tight connections and correct polarity (reverse connection may cause switch failure). After wiring, use a multimeter to test the switch’s on-off status (closed when the door is locked, open when the door is open).

Debugg3. Operation & Daily Maintenance

Remove the wooden wedges fixing the door, restore the power supply, and switch the elevator to inspection mode. Test the door lock function: Close the elevator door to confirm the switch is closed (the elevator control system receives a “door locked” signal); open the door to confirm the switch is open (the elevator cannot start). Operate the door to open and close 10-20 times repeatedly to check the switch’s switching sensitivity and stability. For daily maintenance, inspect the switch during weekly door system patrols: Check if the contact surface is oxidized, burned, or has black spots (clean with contact cleaner if necessary); confirm the fixing screws are tight and the wires are not loose; check the switch’s switching flexibility. Every 3 months, use a multimeter to test the contact resistance (should be ≤ 25mΩ); every 6 months, inspect the switch’s wear degree and replace the contact cleaner if it expires. For elevators in high-humidity or high-dust environments, shorten the maintenance interval to 2 weeks.

Replacement Cycle of Elevator Door Lock Contact Switch SEL1-A1ZP

The replacement cycle of the SEL1-A1ZP door lock contact switch is closely related to the frequency of door opening and closing and the operating environment. Under normal circumstances (elevator daily operation 12-24 hours, daily door opening and closing times ≥ 1000, operating environment dry and low-dust), Nanjing Zhuye Elevatorparts recommends a replacement cycle of 2-3 years. This cycle is determined based on long-term field operation data, contact wear tests, and electrical life assessments, fully considering the wear of the silver alloy contact surface and the aging of insulating materials.
For elevators in high-traffic areas (e.g., large shopping malls, airports with daily door opening and closing times ≥ 2000) or harsh environments (e.g., coastal areas with high salt spray, industrial sites with heavy dust, high-humidity regions), the replacement cycle should be shortened to 1-1.5 years. High-frequency switching accelerates contact wear, while harsh environments cause contact oxidation and insulation aging. For low-usage elevators (e.g., villa elevators, small office buildings with daily operation time < 8 hours) in stable environments, the cycle can be extended to 3-4 years, but only after inspection and confirmation by Nanjing Zhuye’s technicians that the switch’s performance meets safety standards.
Replace the switch immediately if any of the following issues occur, regardless of its service life: The switch fails to switch normally (e.g., remains open when the door is locked, causing the elevator to fail to start; remains closed when the door is open, posing safety hazards); the contact surface is severely oxidized, burned, or pitted, leading to poor contact or frequent false alarms; the contact resistance exceeds 100mΩ (uncorrectable by cleaning); the insulating base is cracked, deformed, or has obvious burns; the switch causes frequent door lock system faults that cannot be eliminated by debugging.
The Elevator Door Lock Contact Switch SEL1-A1ZP from Nanjing Zhuye Elevatorparts integrates safety, durability, and compatibility, providing a solid safety guarantee for elevator door lock systems. By following the correct usage, maintenance, and replacement guidelines, you can effectively ensure the reliable operation of the door lock system, prevent safety accidents caused by door lock failure, and improve the overall safety level of the elevator. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic SEL1-A1ZP door lock contact switches, as well as professional services including model matching, on-site installation guidance, and timely after-sales support. Trust Nanjing Zhuye Elevatorparts for the safety of your elevator door lock system.
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch
Elevator door lock contact switch

 

GET A QUOTE