Products Categories

Elevator hall door triangular lock F9 S8 K8

Elevator hall door triangular lock F9 S8 K8 From-Zhuye Elevator Parts, Full Supply Chain For Otis, Kone, Schindler, Mitsubishi, Thyssenkrupp Elevator Lift  and Escalator All Brand Spare Parts

Share:

Description

Elevator hall door triangular lock F9 S8 K8 Brief Introduction

Product Name

Elevator hall door triangular lock

Model Number F9

S8

K8

 Quality
Original.Brand New
Payment
T/T. Paypal. Western Union
Delivery
3-5 Working Days 
Packaging
Packed by carton

Elevator Hall Door Triangular Lock F9/S8/K8: Safety & Emergency Access Core from Nanjing Zhuye Elevatorparts

Elevator Hall Door Triangular Lock F9/S8/K8 is a critical safety and access control component for elevator hall door systems, covering three mainstream models (F9, S8, K8) to meet the safety and operational needs of different elevator hall door structures. Installed on the elevator landing door panel, it serves dual core functions: daily safety protection and emergency access. Under normal conditions, it locks the hall door to prevent unauthorized opening and avoid falls into the shaft; in emergencies (e.g., elevator breakdowns trapping passengers), maintenance personnel can use a dedicated triangular key to open the hall door quickly for rescue. Each model has targeted advantages: F9 features a anti-theft triangular key slot design, suitable for high-security scenarios like commercial complexes; S8 adopts a one-way rotation locking structure, optimized for residential elevators with simple operation needs; K8 has a built-in safety interlock, which cuts off the elevator operation signal when the lock is opened, ensuring rescue safety. Widely compatible with mainstream elevator hall door models, these triangular locks are essential safety components for various elevator types. Exclusively supplied by Nanjing Zhuye Elevatorparts, a professional provider of high-quality elevator safety components, the Elevator Hall Door Triangular Lock F9/S8/K8 fully complies with international elevator safety standards (EN 81-20, GB 7588) and mechanical lock technical specifications. Manufactured with premium materials and precision machining technology, they feature high structural strength, anti-prying performance, and reliable locking, earning recognition from global elevator maintenance teams and property management companies.
Nanjing Zhuye Elevatorparts adheres to the core philosophy of “Safety Locking, Quick Rescue” and implements rigorous quality control for the F9/S8/K8 elevator hall door triangular locks. Each unit undergoes multi-stage pre-delivery inspections, including locking precision testing, anti-prying performance verification, corrosion resistance detection, and service life evaluation. The triangular locks adopt advanced materials and technologies: the lock body is made of high-strength zinc alloy or stainless steel (optional based on environment), with surface anti-rust treatment (electroplating or powder coating) to adapt to humid and dusty environments in elevator lobbies (-20℃ to 70℃); the internal lock cylinder uses precision copper pins, ensuring smooth key insertion and rotation with over 10,000 times of wear-resistant testing; the built-in safety switch (for K8 model) adopts silver-nickel alloy contacts, ensuring stable signal transmission; the triangular key is made of carbon steel with quenching treatment, avoiding deformation during use. The standardized mounting hole design enables seamless matching with elevator hall door panels, simplifying installation and replacement processes.

Step-by-Step Usage Guide for Elevator Hall Door Triangular Lock F9/S8/K8

To maximize the safety performance, service life, and operational reliability of the Elevator Hall Door Triangular Lock F9/S8/K8, strictly follow the professional guidelines provided by Nanjing Zhuye Elevatorparts for selection, installation, and use:

1. Professional Selection & Pre-Installation Preparation

Installation must be performed by certified elevator technicians. Prior to selection, refer to the elevator’s hall door model, safety system configuration, and usage scenario (consult Nanjing Zhuye Elevatorparts’ technical team if necessary): Choose F9 for high-security areas; S8 for residential or office buildings; K8 for elevators requiring interlock protection. Preparation steps: Cut off the elevator’s main power supply and lock the power switch; place a “Maintenance in Progress” warning sign at the elevator landing; fix the hall door in the closed position with a mechanical support to avoid accidental movement; clean the lock mounting area on the hall door panel to remove dust, oil stains, and debris.

2. Correct Installation & Safety Calibration

  • Lock Body Fixing: Take the matched F9/S8/K8 triangular lock from Nanjing Zhuye Elevatorparts, align it with the preset mounting hole on the hall door panel, and fix it with stainless steel bolts (torque: 15–25N·m). Ensure the lock body is tightly attached to the door panel without shaking, and the key slot is accessible but not easily touched by the public.
  • Interlock Wiring (for K8 model): According to the elevator’s electrical schematic and Nanjing Zhuye Elevatorparts’ wiring manual, connect the K8 lock’s built-in safety switch terminals to the elevator controller’s safety circuit. Ensure tight wiring and correct polarity; use cable ties to fix the wire harness to avoid friction with door components during operation. For F9 and S8 models, skip this step as they do not have interlock functions.
  • Safety Calibration: After installation, insert the dedicated triangular key (provided by Nanjing Zhuye Elevatorparts) to rotate and test the locking/unlocking function. Ensure the lock can lock the hall door reliably, and the door cannot be opened manually when locked. For K8 model, test the interlock function: open the lock with the key, and confirm the elevator controller receives the “lock open” signal and cuts off the operation power; close the lock, and verify the elevator resumes normal operation signal.

3. Standard Operation & Daily Maintenance

  • Emergency Opening Operation: Only authorized maintenance personnel can use the dedicated triangular key. Operation steps: Insert the key into the lock slot (align with the keyway direction); rotate the key 90° clockwise (for F9/S8) or 180° counterclockwise (for K8) until hearing a “click” (indicating the lock is unlocked); pull the hall door open slowly (coordinate with the car position confirmation in advance to avoid safety hazards); after rescue, close the hall door and rotate the key back to the original position to lock it, then pull out the key.
  • Daily Inspection: Maintenance personnel should check the triangular lock during daily patrols: Observe the lock body for damage, corrosion, or loose mounting; check the key slot for blockage by dust or debris; test the locking/unlocking function with the dedicated key to ensure smooth operation. For K8 model, additionally check the interlock wiring for looseness or aging.
  • Regular Maintenance: Every 3 months, clean the lock body, key slot, and internal components with a soft brush and compressed air to remove dust and debris. Every 6 months, apply a small amount of graphite lubricant to the key and insert it into the lock to rotate repeatedly, ensuring smooth operation (avoid using oil-based lubricants which easily attract dust). Keep the dedicated triangular key properly stored and avoid loss or unauthorized use.

Recommended Replacement Cycle for Elevator Hall Door Triangular Lock F9/S8/K8

As a core safety component enduring long-term environmental erosion (humidity, dust, temperature changes), frequent key insertion/rotation, and potential external impact, the F9/S8/K8 elevator hall door triangular lock has a specified service life. Timely replacement is crucial to avoiding faults such as lock jamming, inability to unlock, or safety interlock failure—issues that may lead to inability to perform emergency rescues or unauthorized access to the shaft, posing serious safety risks.

1. Standard Replacement Cycle

Under normal operating conditions (elevator daily operation time 12–24 hours, annual unlocking times ≤ 50, lobby environment temperature -20℃ to 70℃, humidity 10%–95%), the recommended replacement cycle for all three models (F9/S8/K8) is 4–6 years. This cycle is determined based on Nanjing Zhuye Elevatorparts’ long-term field operation data, component aging tests, and global user feedback on elevator safety locks.

2. Adjustments for Special Scenarios

  • High-Frequency Use & Harsh Environments: For elevators in high-traffic locations (e.g., large airports, central shopping malls) with frequent emergency unlocking (annual times ≥ 200), or in harsh environments (e.g., high-humidity coastal areas, high-dust industrial workshops), the replacement cycle is shortened to 2–3 years. Frequent operation accelerates the wear of internal lock cylinders and pins, while harsh environments cause lock body corrosion and structural damage.
  • Low-Frequency Use & Stable Environments: For elevators with low usage frequency (e.g., villa elevators, small office buildings with daily operation time < 8 hours) and stable lobby environments (constant temperature and humidity), the replacement cycle can be extended to 6–8 years—only after Nanjing Zhuye Elevatorparts’ technicians inspect and confirm that the lock’s locking precision, key operation smoothness, and (for K8) interlock performance meet factory standards.

3. Immediate Replacement Conditions

Replace the triangular lock immediately if any of the following issues occur, regardless of its service life:
  • The lock jams and cannot be unlocked or locked normally with the dedicated key, even after maintenance and lubrication.
  • The lock body is severely corroded, cracked, or deformed, affecting the locking stability or structural integrity.
  • For K8 model, the built-in safety interlock fails to transmit signals normally, or the contact resistance exceeds 200mΩ after testing.
  • The key slot is damaged or the internal lock cylinder is worn, leading to key insertion difficulty or inability to trigger the locking mechanism.
In conclusion, the Elevator Hall Door Triangular Lock F9/S8/K8 from Nanjing Zhuye Elevatorparts are high-quality, tailored safety solutions for different elevator hall door systems. By following the correct selection, installation, maintenance, and replacement guidelines, elevator maintenance teams can effectively ensure the reliable operation of the hall door safety system, guarantee timely emergency rescues, and eliminate potential safety hazards. Choosing Nanjing Zhuye Elevatorparts means you get 100% authentic F9/S8/K8 triangular locks, plus professional support—including model matching, on-site installation guidance, and prompt after-sales service. Trust Nanjing Zhuye Elevatorparts for the safety protection of your elevator hall door system.
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock
Elevator hall door triangular lock

 

GET A QUOTE